SAMSUNG Proprietary-Contents may change without notice
7-
10
SGH-V200 Flow Chart of Troubleshooting
U1005 CHECK
pin13 ≥ -65dBm ?
8. EGSM Reciever
CONTI NUOUS RX ON
RF INPUT : 62CH
AMP : -50dBm
NORMAL CONDITION
catch the channel?
U901
pin 12,13≥
-20dBm ?
U1005 CHECK
pin1, 2 ≥ -65dBm ?
U901 CHECK
pin21,22 ≥ -65dBm ?
U902 CHECK
pin 25,28 : 3V ?
Check soldered status of
C1001,C1000
CN1001
resolder or change
U1005
resolder or change
C1003,C1004,L1001
resolder or change
U100pin39 , C116
check or resolder
U902 CHECK
pin 7 : 13MHz ?
Vp-p : 860mV?
OSC801 CHECK
pin 4 : clean 3V ?
U902 change or
resolder
U901 CHECK
pin 14,23,26,32:
clean 2.8V?
C808,R805
resolder
OSC801 change or
resolder
U100pin46, C114
check or resolder
U901 pin3,4
Vp-p : 240mV?
U900 CHECK
pin6, 20 : 2.8V ?
U900
resolder or change
U901 pin1, 2
Vp-p : 250mV ?
U901
resolder or change
U900 pin 2,3,4,5
Vp-p : 100mV ?
CHECK
U700
NO
YES
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
OSC801 CHECK
pin 3 : 13MHz ?
Vp-p : 950mV?
U100pin39 , C116
check or resolder
Содержание SGH-V200
Страница 19: ...SAMSUNG Proprietary Contents may change without notice 4 7 SGH V200 Electrical Parts List M ME EM MO O ...
Страница 28: ...SAMSUNG Proprietary Contents may change without notice SGH V200 Flow Chart of Troubleshooting 7 5 CN10 0 ...
Страница 31: ...SAMSUNG Proprietary Contents may change without notice 7 8 SGH V200 Flow Chart of Troubleshooting ...
Страница 38: ...SAMSUNG Proprietary Contents may change without notice SGH V200 Flow Chart of Troubleshooting 7 15 ...
Страница 39: ...SAMSUNG Proprietary Contents may change without notice 7 16 SGH V200 Flow Chart of Troubleshooting ...
Страница 40: ...ELECTRONICS Samsung Electronics Co Ltd February 2003 Printed in Korea Code No GH68 03689A BASIC ⓒ ...