Flow Chart of Troubleshooting
9-7
This Document can not be used without Samsung's authorization
9-1-3. Camera Part
YES
Check U401, U406
C449 = 2.8V?
C466 = 2.8V?
C450 = 1.5V?
NO
YES
Is there CLK signal at
R617?
Change PBA
NO
YES
Is there CLK signal at
R616?
Replace camera module
NO
YES
END
YES
Replace camera Module
NO
Check the camera FPCB.
Is the camera FPCB OK?
YES
YES
Reconnection camera connector
NO
Is the connection of
camera and PBA OK?
Camera does not work