SAMSUNG Proprietary-Contents may change without notice
This Document can not be used without Samsung's authorization
Flow Chart of Troubleshooting
9-26
9-12. DCS Receiver
Yes
CONTINUOUS RX on
RF input : 698CH
Cell power : -50dBm
RX ON
RF input : 698CH
Cell Power : -50 dBm
Yes
No
Resolder RFS101
C105
≥
-65dBm
C134 > 2.5V
C165 > 1.5V
C166 > 1.5V
C174 > 1.5V
Yes
Check UCP301
No
Yes
L107
≥
-68dBm
No
Resolder or Change MOD101
Yes
No
Check UCP301
Check U101
U101 PIN
11,12,13,14
≥
500mV
END