SAMSUNG Proprietary-Contents may change without notice
SGH-E880 Flow Chart of Troubleshooting
2-
17
This Document can not be used without Samsung's authorization
F700 CHECK
pin#13
≥
-65dBm
2-2-3. PCS RX
CONTINUOUS RX ON
RF INPUT : 660CH
AMP : -50dBm
NORMAL CONDITION
catch the channel
Check soldered status of
C734, C737
U700
pin #9, #32 = 2.8V
F700 CHECK
pin#5,#6
≥
-65dBm
U700 CHECK
pin#16,#17
≥
-65dBm
C725,CN700
resolder or change
F700
resolder or change
C732,C733,L707
resolder or change
Check the pin A13 of the U100
U700 CHECK
pin #8 : 13MHz &
Vp-p : 950mV
OSC700
resolder or change
U700
resolder or change
U100 CHECK!!
U700
pin#1,#2,#3,#28
Vp-p= 100mV
YES
NO
NO
NO
NO
NO
NO
YES
YES
YES
YES
YES
YES
NO