Flow Chart of Troubleshooting
3-14
3-2. RF
3-2-1. GSM Rx
Normal condition
catch the channel ?
Check U304
pin #11
≥
-65
dbm ?
Check UCD101
pin #29,30
≥
-65dBm ?
Yes
No
No
Check U304
pin #17
≥
-65
dbm ?
Yes
No
Yes
Check ANT,
C126, L102
Check and resolder or change
RFS100, C101, L111, L100, L101, C102
Resolder or change
U304
Check and resolder or change
F101, C105, C109, L104
Resolder or change
UCP200
CONTINOUS RX ON
RF INPUT : 62CH
AMP : -50dbm
Check UCD101
pin#13 = 2.9V?
Yes
Resolder or change
UCD101
Yes
No
No
1
2
3
4