background image

12

Samsung Electronics

N O

C O D E - N O

P A R T

S P E C

Q ’ T Y

R E M A R K

3 7

3 8

3 9

4 0

4 1

4 2

4 3

4 4

4 5

4 6

4 7

4 8

4 9

5 0

5 1

5 2

5 3

5 4

5 5

5 6

5 7

5 8

5 9

6 0

6 1

6 2

6 3

6 4

6 4 - 1

6 5

6 6

6 7

6 8

6 9

7 0

7 1

7 1 - 1

7 2

7 3

D A 6 3 - 3 0 1 7 7 A

D A 7 2 - 2 0 1 3 2 A

D A 6 7 - 3 0 2 2 7 A

D A 9 1 - 1 0 1 0 2 A

6 0 0 2 - 0 0 0 4 5 3

D A 7 1 - 4 0 1 3 2 A

*D A 3 9 - 2 0 2 5 8 A

*D A 3 9 - 2 0 2 6 5 A

*2 5 0 1 - 0 0 0 5 1 1

*2 5 0 1 - 0 0 0 4 2 2

*2 5 0 1 - 0 0 0 4 2 7

D A 6 7 - 1 0 1 7 6 B

6 0 0 2 - 0 0 0 4 7 0

6 0 0 2 - 0 0 0 4 7 0

D A 7 4 - 3 0 1 4 9 A

D A 7 4 - 3 0 1 5 0 A

D A 6 0 - 1 0 1 2 0 A

D A 7 1 - 1 0 2 6 5 A

D A 6 1 - 3 0 1 1 0 A

D A 6 1 - 1 0 1 3 5 A

D A 6 0 - 1 0 1 2 0 A

D A 7 3 - 1 0 1 3 9 A

D A 6 0 - 2 0 0 0 8 B

D A 6 5 - 2 0 1 1 3 A

D A 6 3 - 1 0 7 2 2 A

D A 3 5 - 1 0 0 0 3 D

D A 3 5 - 1 0 0 0 3 H

D A 3 4 - 1 0 0 0 3 V

D A 3 4 - 1 0 0 0 3 R

D A 7 3 - 1 0 1 4 0 A

D A 6 3 - 4 0 1 4 3 A

D A 7 1 - 6 0 1 1 3 A

D A 6 0 - 1 0 1 2 0 A

D A 7 3 - 3 0 1 0 5 B

D A 7 3 - 1 0 3 1 2 A

*S D 1 6 2 H - L I U

*S D 1 6 2 C - L I W

D A 6 5 - 2 0 1 1 6 A

6 0 0 2 - 0 0 0 4 5 3

ASSY-GASKET DOOR

P A N E L - D O O R

CAP-SCREW, HOLE

ASSY-DOOR FOAM

SCREW-TAP, FH

S T O P P E R - D O O R

ASSY-LEAD WIRE RELAY

ASSY-LEAD WIRE RELAY

C A P A C I T O R - R U N N I N G

C A P A C I T O R - S T A R T I N G

C A P A C I T O R - R U N N I N G

E N C L O S U R E - S P L I C E

SCREW-TAP, TH

SCREW-TAP, TH

D R A I N - F R E

D R A I N - F R E ( B )

SCREW-TAP TITE

REINF-HINGE LOW

L E G - A S S Y

H I N G E - L O W

SCREW-TAP TITE

TUBE-CONNECT SUCT

BOLT-HEX COMP

CLAMP-RELAY COVER

C O V E R - R E L A Y

P T C.R E L A Y

P T C.R E L A Y

O/L PROTECTOR

O/L PROTECTOR

TUBE-CONNET DISCG

G R O M M E T - C O M P

C H A S S I S - C O M P : S B H G 1

SCREW-TAP TITE

D R Y E R

ASSY-SUB CONDENSER

C O M P R E S S O R

C O M P R E S S O R

C L A M P - T H E R M O

SCREW-TAP, FH

S F R - A 2 1 N F A

ABS T1.2

A B S

S F R - A 2 1 N F A

1-4x12 STS304

SCP1 + ZPC3 T2 W20.5 L43

SFR-A21NFA, 220~240V/50

SFR-A21NFA 110V

SFR-A21NFA, 250VAC/12µF-110V

SFR-A21NFA, 125VAC/100µF-110V

220~240V150 350VAC/35µF

SBHG1 T0.8

1-4x10 FE, FZY

1-4x10 FE, FZY

ABS W9540 SFR-A21NFA

ABS W9540 SFR-A21NFA

ZPC2-Y 6X16 SR-53EA

SCP1 + ZPC3 T2.5 L92

NY6 + MSWR10 PI28 H46

SCP1 T2.5 ZPC3

ZPC2-Y 6X16 SR-53EA

C1220BD-0 0D6.35 TO.5

SM30C L46.6

S K - 5

P.P V451

PTHAS-T330M 385D 220V

PTHAS-T100M 200B 110V

4TM 265RHBYY-53 220V

4TM 427PHBYY-53 110V

0D4.76 T0.5

NBR BLK H31.8

SBHG1 T1.2 SFR-A21NFR

ZPC2-Y 6x16

5.0 Gr

S F R - A 2 1 N F A

SD162H-LIU : 220V/50~60H

Z

SD162C-LIW : 110V/60H

Z

A L

1-4x12 STS304

1 . 0

1 . 0

1 . 0

1 . 0

2 . 0

1 . 0

1 . 0

1 . 0

1 . 0

1 . 0

1 . 0

1 . 0

2 . 0

6 . 0

1 . 0

1 . 0

1 . 0

1 . 0

2 . 0

1 . 0

4 . 0

1 . 0

4 . 0

1 . 0

1 . 0

1 . 0

1 . 0

1 . 0

1 . 0

1 . 0

4 . 0

1 . 0

4 . 0

1 . 0

1 . 0

1 . 0

1 . 0

1 . 0

2 . 0

Indicated part is for electrical safety components

Содержание SFR-A21NFA

Страница 1: ...uct specifications 3 Circuit Diagram 4 Specification of Electric Components 5 Product structure Temperature adjustment 6 Product Dimension 7 Refrigerant Gas Circulation Diagram 8 How to replace main components 9 How to change the direction of door open 10 Exploded view Parts list ...

Страница 2: ...ELECTRONICS Samsung Electronics Co Ltd Jul 1998 Printed in Korea C ...

Страница 3: ...sing severe personal injury Make sure the power cord is not crushed or damaged Repair immediately all power cords or outlets that have become frayed or otherwise damaged Check the operating environment Do not install the refrigerator in a humid with condensation location or on an unstable surface Do not use the refrigerator if it is not operating correctly or has been damaged Disconnect it from th...

Страница 4: ...ousing electric connections and etc This can protect against the risk of fire hazard caused by tracking and short circuit When replacing electric components be sure to use rated components Check the model rated voltage rated current operating temperature etc of the component When servicing the refrigerator completely remove dust or foreign substances from the housing electric connections and etc T...

Страница 5: ...DEL NAME SFR A21NFA Power 110V 60HZ Power 220V 50 60HZ GRY S BLU GRY GRY GRY COMPRESSOR P T CRELAY OVER LOAD PROTECTOR CONDENSER STARTING GRY S BLU GRY BLK CONDENSER RUNNING RED POWER SWITCH BLK Super S W YEL N A THERMOSTAT GRY S BLU GRY GRY GRY GRY S BLU COMPRESSOR P T CRELAY OVERLOAD PROTECTOR CONDENSER RUNNING RED POWER SWITCH BLK Super S W YEL N A THERMOSTAT GRY GRAY YEL YELLOW BLK BLACK RED R...

Страница 6: ... Overload Relay Earth Screw Running Starting Specifications Capacitor SFR A21NFA 4 STAR 53 kg FREOL α15C 200CC PIPE CAULKING TYPE CLUSTER TYPE HOT LINE BUILT IN MOLECULARSIEVE 5 7 12Kg cm2 2 5m R 134a ON C 24 6 2 20 5 1 5 16 3 2 OFF C 30 4 2 25 5 1 5 20 7 2 WARNING ON OFF 18 5 2 15 0 2 12 7 2 PTHAS T100M200B 10Ω 20 4TM427PHBYY 53 69 9 C 125 5 C 250VAC 12µF 125VAC 100µF BSBN BRASS SCREW M4x10 PTHAS...

Страница 7: ...han 5 minutes after power off If the power is immediately turned on after power off trouble could be caused by operation by force Super If the amount of frozen food is much quick ice making or quick freezing is required Press the super freezing H button Yellow display lamp is on Turn it off by pressing the button when the inside of freezer is frozen fully Power consumption can be reduced Normal It...

Страница 8: ...6 Samsung Electronics 6 Product Dimension ...

Страница 9: ... Gas Circulation Diagram Kinds of welding 25 silver solder welding 0 silver solder welding FLASH BUTT welding AI Cu ARGON welding AI AI Condenser Hot pipe Capillary tube Dryer Compressor Suction pipe Evaporator Refrigerant charging tube ...

Страница 10: ... outlet 2 Open the door and take out the compartments 1 and 2 3 Remove the thermostat sensor K part 4 Remove the thermostat box from the back of freezer 5 Remove the wire from the thermostat 6 Disassemble the condenser plate and remove the thermostat from the freezer 7 Reassemble them in opposite order of disassembly ...

Страница 11: ... 2 3 after leaning the freezer backward and removing bolts and exchange and reassemble them 5 Reassemble the component 7 to the opposite side screw of component 6 and reassemble the door and the component 6 to its opposite side At this time door should be balanced 2 Disassemble the door after removing the components 4 5 6 7 in order Remove the door by pulling it up When removing the component 6 ta...

Страница 12: ...0 42 41 25 25 1 25 2 25 3 31 18 17 21 14 7 12 6 8 9 13 51 52 54 53 55 57 58 59 61 60 62 63 64 64 1 71 1 71 66 67 68 65 56 69 48 50 16 43 44 47 46 45 49 70 5 4 2 1 3 15 11 10 12 1 11 1 10 1 20 22 19 30 10 Exploded view parts list 10 Samsung Electronics ...

Страница 13: ...UTTON INLAY TOP TABLE INSULATION TUBE ASSY SUCT PIPE ASSY EVAP UP ASSY EVAP MD ASSY EVAP LW STOPPER TRAY L STOPPER TRAY R SCREW TAP TH TRAY ICE TRAY ICE TRAY TRAY UP TRAY UP TRAY UP TRAY UP TRAY LW KNOB INDICATOR A INDICATOR B INDICATOR C CAP DIAL ENCLOSURE THERMO SCREW TAP TH THERMOSTAT KNOB DIAL SCREW TAP TH SFR A21NFA PEARL WHITE SCP1 T2 5 ZPC3 SM30 ZPC3 H35 5 HM 5X16 TSFE FZY ABS H40 L590 5 AB...

Страница 14: ...ASSY HINGE LOW SCREW TAP TITE TUBE CONNECT SUCT BOLT HEX COMP CLAMP RELAY COVER COVER RELAY PTC RELAY PTC RELAY O L PROTECTOR O L PROTECTOR TUBE CONNET DISCG GROMMET COMP CHASSIS COMP SBHG1 SCREW TAP TITE DRYER ASSY SUB CONDENSER COMPRESSOR COMPRESSOR CLAMP THERMO SCREW TAP FH SFR A21NFA ABS T1 2 ABS SFR A21NFA 1 4x12 STS304 SCP1 ZPC3 T2 W20 5 L43 SFR A21NFA 220 240V 50 SFR A21NFA 110V SFR A21NFA ...

Отзывы: