background image

6. Schematic diagram of coolant circulation

8

SR-21/24 NME(WME)

COMPRESSOR 

CLUSTER  PIPE  

HOT PIPE 

DRYER 

CAPILLARY TUBE   

EVAPORATOR 

ACCUMULATOR 

SUCTION PIPE 

COMPRESSOR

PIPE-CLUSTER,B

PIPE-CLUSTER,A

DRYERA

ACCUMULATORB

EVAPORATOR

HOT-PIPE

SUCTION

PIPEA

COMPRESSOR

CAPILLARY TUBE

Содержание S-23ENV

Страница 1: ...rical part specifications standard 4 Productdimension 5 Identifyinganddisassemblingtheparts 6 Schematicdiagramofcoolantgascirculation 7 Circuitdiagram 8 Packingdimensin 9 Schematicsiagramofcoldairflow 10 Troubleshootingmethod 11 Explodedview partlist Model SR 21NME 21WME SR 24NME 24WME ...

Страница 2: ... appliances into the same outlet This may cause abnormal heating or fire hazard Do not attempt to make repairs yourself This could lead to fire hazard or abnormal operation causing severe personal injury Make sure the power cord is not crushed or damaged Repair immediately all power cords or outlets that have become frayed or otherwise damaged Check the operating environment Do not install the ref...

Страница 3: ...mperature etc of the component When servicing the refrigera tor completely remove dust or foreign substances from the housing electric conne ctions and etc This can proect against the risk of fire hazard caused by tracking and short circuit Whenservicingtherefrigerator completelyremovedustorforeign substancesfromthehousing electricconnectionsandetc Thiscanprotectagainsttheriskoffire hazardcausedby...

Страница 4: ...or AC 115V 60HZ 127V 60Hz 220V 50 60Hz 230 240V 50Hz D 134a 130gr Dial Thermostat Automatic Start Finish by Timer R 141b R 141b ABS 1 Refrigerator 2Legs Front 2 Guard freezer 1 Guard egg 1 Guard variety 2 Guard bottle 2 Guard freezer 1 Guard egg 1 Guard variety 2 Guard bottle 1 Base tray ice H 1 Case tray ice assy H 1 Tray ice cube 1 Shelf0freezer sub H 1 Cover vegetable 1 Tray vegetable 2 Shelf r...

Страница 5: ...Dryer Capillary tube SR 21NME 21WME SR 24NME 24WME R S C R FREOL α 15c 200cc Split fin type Forced natual convection Molecular sieve I D 0 75 x 3400 mm 8032 D705 E9C 115V 60HZ SD152C L1W2 C S R Type Oper temp Regularity Oper temp TMDE714F1 4TM427 PHBYY 53 4TM265 PHBYY 53 61 9 125 5 912X32E100MQ16APE2 33Ω 20 4TM222 PHBYY 53 AC250V 5A ON 5 3 OFF 12 3 AC 250V 10A 72 4 TMD706SC1 6Hr 35min 13min 40s 91...

Страница 6: ...4 Product Dimension 6 SR 21 24 NME WME 1071 0 500 0 9 5 366 5 545 0 59 5 51 0 B A 545 0 77 5 MODEL SR 21NME 21WME SR 24NME 24WME A 1453 1553 B 874 5 974 5 Remark ...

Страница 7: ... cover to the right until the mounting hook disengages then disengage the other mounting hook and pull out the cover Pull the shelf forward until it stops Then lift it up and pull it out To remove door bins While pushing the bin to the left left it up to disengage To remove shelves in the refrigerating compartment Hold the shelf by the front and pull it forward of the rack To remove storage drawer...

Страница 8: ...culation 8 SR 21 24 NME WME COMPRESSOR CLUSTER PIPE HOTPIPE DRYER CAPILLARY TUBE EVAPORATOR ACCUMULATOR SUCTIONPIPE COMPRESSOR PIPE CLUSTER B PIPE CLUSTER A DRYERA ACCUMULATORB EVAPORATOR HOT PIPE SUCTION PIPEA COMPRESSOR CAPILLARY TUBE ...

Страница 9: ...HT WHITE BLU BLUE S BLU SKY BLUE RED RED RED RED R LAMP W BLK DOOR S W L E N 1 2 3 4 7 2 SR 21 24WME F M M L YEL WHT MOTOR PLMP WATER DISPENSER MICRD S W LED BRN BRN RED RED RED BLK GRY PNK ORG M C 1 2 3 S 6 5 2 3 S BLU S BLU S BLU BLU P T C RELAY F THERMOSTAT POWER PCB THERMO FUSE FAN MOTOR COMPRESSOR DEFROST TIMER DEFROST HEATER OVERLOAD PROTECTOR BIMETAL THERMO RUNNING CONDENSER GRY GRY GRAY RE...

Страница 10: ...8 Packing dimension 10 SR 21 24 NME WME MODEL SR 21NME 21WME SR 24NME 24WME A 636 636 B 596 596 C 1581 1681 Remark ...

Страница 11: ... as as well as to the shelves from the cold air exhaust port food is frozen in the freezing compartment by cold air shower Cold air that comes out of the freezing compartment is absorbed back to the lower part fo the cooling system through the suction port on the median divider In the refrigerating compartment cold air is distributed to the damper cover through the medien divider coner through the...

Страница 12: ...blem Make sure the refrigerator is plugged in at the wall outled Makesurethat thethermometerinthefreezer compartmentiselectrcally connected Chesk the defrost timer Check the P T C relay Check the overload relay Check the condenser Thecompressorisdefective Replacethedefectivepart If the fan operates when you push the door switch it is normal Replace if it is defective Replacethedefectivepart Checkt...

Страница 13: ...oling fan operate Is too much food stored in the freezer compartment Is the freezer defrosted normally Is the door closed properly Is the door stopper hinge normal Check the cooling fan motor Check the door swittch Defrost timer Temperature fuse Bimetal thermometer Defrost heater Check that the door gesket is properly seled check for the damaged gasket Correct or readjust the door stopper hinge Ti...

Страница 14: ...g the leaked spot replace the refrigerant Symptom Cause Suggestions TheEVAPcoolsdownandwarmsagain Thecondenserwarmsinproportinasthe EVAPcools Theprocesscontinuestorepeat The condenser is cold The EVAP is not cold The temperature of the comrressor is high No difference in temperatures detween suction pipe and discharge pipe The temperature of the compressor is maintained at room temperature The EVA...

Страница 15: ...resistance Use the tester to measure the resistance Bring the component to cool down completely before measuring Use the tester to measure the resistance Components Diagnosing methods and criteria Location Mechanical compartment Mechanical compartment Electrical equipment box Mechanical compartment Mechanical compartment Freezing compartment Refigerating compartment Between the upper and the lower...

Страница 16: ...11 Exploded View Parts List 16 SR 21 24 NME WME 11 1 Freezing compartment 6 9 7 8 10 26 11 12 13 14 15 16 24 16 18 19 20 20 4 23 22 21 3 25 2 1 ...

Страница 17: ...PP 5 DA67 20323A SHELF FREEZER SUB GPPS 6 DA64 00363A KNON F THERMO HIPS 7 DA39 20410A WIRE HARMESS THERMO 110 240V 8 DA47 10167A THERMOSTAT MARCOT 8032 9 6002 000470 SCREW TAP TH M4 0 L10 10 DA72 40478A COVER EVAP REAR FOAM PS DA72 40478B COVER EVAP REAR FOAM VO 11 DA61 20149A SPRING FAN STS27WR 12 DA31 20138A FAN ABS 13 DA71 50233A BRACKET MOTOR ABS DA71 50233B BRACKET MOTOR VO 14 DA63 40289A GR...

Страница 18: ...11 2 Refrigerating compartment 18 SR 21 24 NME WME 11 12 17 15 16 9 4 3 2 1 10 17 13 14 6 7 8 5 ...

Страница 19: ... 00677A Cover Chil Room Gpps Screen E Type 13 DA67 20326B Shelf Wire Ref MSWR10 14 DA64 20206D Trim Shelf Ref PVC 15 DA63 11053A Cover Tray Vegetable GPPS 16 DA67 00448A Tray Vegetable GPPS Screen E Type 17 DA67 20322A Shelf Ref GPPS 18 DA67 10465A Contorol Humidity Veg HIPS NO CODE NO Iterms Specifications N SAFETY 110 127V 60Hz SR 21 NME SR 24 NME SR 21 NME SR 24 NME SR 21 NME SR 24 NME SR 21 NM...

Страница 20: ...11 3 Door parts 20 SR 21 24 NME WME 1 2 9 3 3 4 5 6 6 8 7 11 10 ...

Страница 21: ...0 00833A Assy Door Foam Ref SR 24NM E TYPE Key DA90 00833B Assy Door Foam Ref SR 24NM E TYPE Key DA90 00833L Assy Door Foam Ref SR 24NM E TYPE Key DA90 00833M Assy Door Foam Ref SR 24NM E TYPE Key 3 DA63 00684A Guard Freezer GPPS E Type 4 DA63 00683A Guard Egg GPPS E Type 5 DA63 00680A Guard Variety GPPS E Type 6 DA63 00681A Guard Bottle A GPPS E Type 7 6001 000701 Screw Machince M4 L12 8 DA71 401...

Страница 22: ...11 4 Cabinet Parts Unit 22 SR 21 24 NME WME 17 16 13 20 19 11 11 12 10 8 5 7 6 7 9 17 24 13 14 15 16 30 18 29 28 26 27 25 24 23 22 21 4 1 2 3 ...

Страница 23: ...lay SD162H L1U2 912X35E33MT20APE2 DA34 10003V O L Protector SD162H L1U2 4TM265RHBYY 53 DA59 50003A Compressor SD162Q L1U2 240V 50Hz DA35 10003D PTC Relay SD162Q L1U2 PTHAS T33M385D DA34 10003K O L Protector SD152H L1U2 4TM222PHBYY 53 DA60 20008A Bolt Hex SM30C L42 6 16 DA63 10722A Cover Relay PP V451 17 DA63 40143A Grommet Comp NBR ID10 H9 7 NO CODE NO Iterms Specifications SR 21 24NME N Safety SR...

Страница 24: ...un 3 2UF 350VAC 2501 000278 C oil Start 12UF 250VAC 28 DA63 40171B Grommet Discharge NR ID4 29 DA63 40171D Grommet Discharge NR ID6 30 DA73 30111A Dryer C122OT OD18 85 ID4 75 L100 NO CODE NO Iterms Specifications SR 21 24NME N Safety SR 21 24NME Safety M G 110 127V 60HZ 110 127V 60HZ 110 127V 60HZ 110 127V 60HZ 110 127V 60HZ 110 127V 60HZ 1 1 2 1 1 1 1 2 1 1 1 1 L G 1 1 2 1 1 1 1 2 1 1 1 1 S W 1 1...

Страница 25: ...11 5 Assy water dispenser parts 25 SR 21 24 NME WME ...

Страница 26: ...S MG DA63 00517L Cover dispenser SR 21 24WME ABS SW DA63 00517L Cover dispenser SR 21 24WME ABS TO 4 DA63 00518A Cover button SR 21 24WME ABS GRY 5 DA64 00267A Button switch SR 21 24WME NY 66 NTR 6 DA39 00137A W H dispenser SR 21 24WME 7 6003 000334 Screw tap TH SR 21 24WME M3 8 8 6002 000526 Screw tap TH SR 21 24WME M4 12 9 6002 000367A CAP SCREW SR 21 24WME ABS LG 6002 000367F CAP SCREW SR 21 24...

Страница 27: ... c SR 21 24WME 19 DA62 00026A Filter qater line c SR 21 24WME 20 DA63 00522A Cover water dispenser SR 21 24WME 21 DA41 00067A PBA MAIN SR 21 24WME 22 DA61 00170A Case junction SR 21 24WME NO CODE NO Iterms Specifications SR 21NME LG MG SW TO LG MG SW TO SR 24NME 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 ...

Страница 28: ...MEMO 28 SR 21 24 NME WME ...

Страница 29: ... Samsung Electronics Co Ltd May 2001 Printed in Korea ELECTRONICS ...