6
A
◆
RJ050F2HX**
◆
Piping length and the helght
◆
Piping outside diameter
※
The appearance of the unit may be different from the diagram depending on the model.
※
The appearance of the unit may be different from the diagram depending on the model.
200 mm
or more
160 mm
or more
Main power switch
100 mm
or more
A
B
(h)
(H)
300 mm
minimum
300 mm
minimum
600 mm
minimum
CAUTION
3 m as minimum pipe length: It will reduce noise and
vibration.
Make at least one round:
It will reduce noise and vibration
Indoor unit
Outdoor unit
Power supply 0, V, Hz
**020/023/026/
035/052
07/09/12/18**
RJ050F2HX**
1,220-240,50/60
Unit
Outside diameter
Liquid
Gas
**020/023/026/
030/035/07/09/12**
1/4"
3/8"
**052/18**
1/2"
※
RJ050F2HX** Outdoor unit cannot be connected to the following indoor unit combination.
- MH052FMEA/MH052FUEA
1 Room max
length
2 Room total max
length
Max height between
indoor unit & outdoor unit
Max height between
indoor units
Dimension
20m
30m
15m
7.5m
Composition
A,B
A+B
(H)
(h)
Deciding on Where to Install the Air Conditioner
600 mm
minimum