63
TROUBLESHOOTING
- If defrost has trouble, select the self-diagnostic function to detect the error of defrost heater before
Power Off. (Check the function with refer to the self-diagnostic function)
4-2-4. If defrost does not operate (F,R DEF Heater)
R DEF ERROR
F DEF ERROR
Start
Are the all deforst
heater normal?
Check the bimetal, heater
disconnection, wiring connection etc.
Refer to self-diagnostic
function in the manual
Replace the
applicable sensor
manual operation for a certain time
Manual defrosting of fresh food
and freezer compartments
operate simultaneously.
Resistance value of sensor according to temperature
If you need the
temperature with detail,
refer to DATA1.
temperature
table
**Measuring point of resistance value according to sensor **
F-DEF : CN30#4 CN75#1 measuring resistance value
R-DEF : CN30#7 CN75#1 measuring resistance value
** 0 : Short trouble /
: Open trouble
**Measuring point of resistance value according to heater**
F-DEF : CN70#9(Brown) CN71#9(Orange) measuring
resistance value(55(220) ohm 7%)
R-DEF(Ice Pipe parallel) : CN70#7(White) N71#9(Orange)
measuring resistance value(105(407) ohm 7%)
** 0 : Short trouble /
: Open(bimetal, heater) trouble
86 (30 )
68 (20 )
50 (10 )
32 (0 )
14 (-10 )
-4 (-20 )
-22 (-30 )
4.22
6.05
8.87
13.29
20.42
32.23
52.41
If Power Freeze Key + Fridge Key are pressed
simultaneously for 8 seconds and then select any key,
3rd test mode(manual defrosting) will be operated.
Is the temperature of
defrost sensor lower
than 53.6 (12°C)?
Is defrost sensor by
self-diagnostic normal?
Is power applied to
each defrost heaters?
Is connection terminal of
MAIN PCB part normal?
Recheck the applicable
sensor.
**Measuring point of resistance value according to sensor **
F-DEF : CN30#4 CN75#1 measuring resistance value
R-DEF : CN30#7 CN75#1 measuring resistance value
** 0V: Short trouble / 5V: Open trouble
Normal
Repair connection terminal
Reference
If defrost sensor
temperatures of fresh food and
freezer compartments are higher
than 50 (10 ), 53.6 (12 ) by
the heating from heater, heating
would be finished and will return
to cooling operation after a pause.
Check bimetal, heater itself,
disconnection etc.
Replace failure Relay or
replace PCB ASS'Y
Does the system return
to cooling operation after
heating for specified time?
Checking method of F,R DEF Heater resistance value
F FEF ; CN70#9(Brown)
CN71#9(Orange)
R FEF ; CN70#7(White)
CN71#9(Orange)
- Recheck if resistance values are different after the test
1) F DEF Heater
2) R DEF Heater
Содержание RF265AB
Страница 17: ...18 Refrigerator PRODUCT SPECIFICATIONS 2 9 Cooling Air Circulation Freezer ...
Страница 73: ...74 EXPLODED VIEW PARTS LIST 5 1 Freezer 19 20 20 4 20 3 20 4 20 2 20 1 ...
Страница 76: ...77 EXPLODED VIEW PARTS LIST 5 2 Refrigerator ...
Страница 80: ...81 EXPLODED VIEW PARTS LIST 5 3 Cabinet 38 ...
Страница 84: ...85 EXPLODED VIEW PARTS LIST 5 4 Disassembly of Freeze Door ...
Страница 86: ...87 EXPLODED VIEW PARTS LIST 15 2 DA61 04335A SPRING ETC EASY HANDLE 08 AW1 2 PJT HSWR PartsListofFreezerDoor ...
Страница 87: ...88 EXPLODED VIEW PARTS LIST 5 5 Disassembly of Refrigerator DoorLeft ...
Страница 90: ...91 EXPLODED VIEW PARTS LIST 5 6 Disassembly of Refrigerator Door Right ...
Страница 98: ...99 7 WIRING DIAGRAM SCHEMATIC 7 1 Model RF266 100 7 2 Model RF265 101 ...
Страница 101: ...102 8 CIRCUIT PLAN 8 1 Whole block diagram 103 8 2 CIRCUIT DIAGRAM 105 ...
Страница 102: ...103 8 1 Whole block diagram 8 Shematic Diagram AC115V AC115V AC115V 8 1 1 MODEL RF266 BETTER ...
Страница 103: ...104 Shematic Diagram AC115V AC115V AC115V 8 1 2 MODEL RF265 GOOD ...
Страница 104: ...105 8 2 CIRCUIT DIAGRAM Shematic Diagram 8 2 1 Sheet 1 of 2 ...
Страница 105: ...106 8 2 CIRCUIT DIAGRAM Shematic Diagram 8 2 2 Sheet 2 of 2 ...