STATUS INDICATOR  

Mode

Status

Display

Function

Status

Compressor On

This icon indicates that the compressor in the outdoor 
unit is running.

Back-up heater 
On

This icons indicate that the backup heater of the unit 
is operating, when there is a high demand for heating 
capacity. The backup heater provides extra heating 
capacity in case of low ambient outdoor temperature 
(high heating load).

Booster heater 
On

This icon indicates that the booster heater is active. 
The  booster heater provides auxiliary heating for the 
domestic hot water tank. The  booster heater is located 
in the domestic hot water tank. The icon is not used 
when the domestic hot water tank is not installed.

Solar thermal 
panel On

It indicates when the solar panel is powered on. DHW 
mode is stopping while solar panel is on in order to save 
your energy cost. 

Back up boiler 
On

The Back up boiler shall start to work as soon as 
outdoor temperature reach to the targeted temperature.
Users can adjust the temperature to allow the back up 
boiler work. The icon shall not be displayed without the 
Installation of the back up boiler. 

Water pump On

This icon indicates that the circulation pump is active.

Domestic water 
On

This icon indicates when the domestic water heating 
mode is operating.

Defrost 
operation On

This icon indicates that the defrost mode is active.

Anti freezing 
operation On

The system automatically maintains the water 
temperature above a freezing point to prevent from 
freezing-fracture of piping system.

Sanitary 
operation On

This function disinfects the DHW tank by periodically 
heating the domestic water to a specific temperature.

RC120MHXGA_IB_E_00000A(1).indd   13

2011-10-13   오후 3:41:45

Содержание RC160MHXGA

Страница 1: ...t To receive more complete service please register your product at www samsung com register Control Unit RC120MHXGA RC140MHXGA RC160MHXGA RC090MHXEA RC120MHXEA RC140MHXEA RC160MHXEA DB98 00000A 1 I F S E P D RC120MHXGA_IB_E_00000A 1 indd 53 2011 10 13 오후 3 42 21 PDF processed with CutePDF evaluation edition www CutePDF com ...

Страница 2: ... a location where gas may leak This may result in electric shock or fire Never install the outdoor unit in a location such as on a high external wall where it could fall If the outdoor unit falls it may result in injury death or property damage This appliance must be properly grounded Do not ground the appliance to a gas pipe plastic water pipe or telephone line Failure to do so may result in elec...

Страница 3: ... a gas leak such as propane gas LP gas etc ventilate immediately without touching the power plug Do not touch the appliance or power cord Do not use a ventilating fan A spark may result in an explosion or fire To reinstall the air conditioner please contact your nearest service center Failing to do so may result in problems with the product water leakage electric shock or fire A delivery service f...

Страница 4: ...result in electric shock fire or problems with the product Do not drink the water from the air conditioner The water may be harmful to humans Do not apply a strong impact to the remote controller and do not disassemble the remote controller Do not touch the pipes connected with the product This may result in burns or injury Do not use this air conditioner to preserve precision equipment food anima...

Страница 5: ... solar panel is powered on DHW mode is stopping while solar panel is on in order to save your energy cost Back up boiler On The Back up boiler shall start to work as soon as outdoor temperature reach to the targeted temperature Users can adjust the temperature to allow the back up boiler work The icon shall not be displayed without the Installation of the back up boiler Water pump On This icon ind...

Страница 6: ...n order to provide domestic hot water throughout the day it is advised to keep the domestic water heating operation on continuously When the icon is displayed hot water is delivered to the DHW tank by the solar panel The operation between solar panel and heat pump can be determined by using Wired Remote Controller s Field Setting Mode 2 Press Mode DHW mode button until required operating mode is d...

Страница 7: ...r temperature to save energy cost 1 Press Outing Hot key The heat pump delivers heat at a low temperature If the Power Space mode button has not been turned on this key does not work To cancel the outing mode 1 Press Outing Hot key once again to exit The heat pump is turned on a normal operation It will return to a normal heating mode or DHW mode RC120MHXGA_IB_E_00000A 1 indd 21 2011 10 13 오후 3 41...

Страница 8: ...Delete button To cancel the setting press the Cancel Delete button 2 Set the day by pressing Up or Down button The day indicator will blink Set the day and press Set button to save the setting 3 Set the hour by pressing Up or Down button The hour indicator will blink Set the hour and press Set button to save the setting 4 Set the minute by pressing Up or Down button The minute indicator will blink...

Страница 9: ... Daily button The mode changes to the Daily schedule In this mode you can only use Up Down Daily Set Cancel Delete button To cancel the setting press Cancel button 2 Set the On Off by pressing Up Down button The On Off indicator will blink Set the On Off status and press Set button to save the setting 3 Set the operation mode by pressing Up or Down button The operation indicator will blink Set the...

Страница 10: ...tton to save the setting 6 Confirm the Schedule After step 5 all indicators are blinking except Reservation No Daily Then press Set button On this step you can only use Set or Cancel Delete button If there is a reservation on the same day and time it will not be confirmed and Not Available indicator will blink for 3 seconds In this case go back to the step 4 Viewing the Daily Schedule On Off Displ...

Страница 11: ...matically according to schedule 2 If On schedule starts during the Urgent DHW mode the Urgent DHW mode will be turned off In the following conditions the schedule function will not operate Outing Tracking of communication Installation of room thermostat If the field setting is set for without DHW or another manufacturers tank is used it is not possible to reserve DHW mode If the field setting is s...

Страница 12: ...RC120MHXGA_IB_E_00000A 1 indd 52 2011 10 13 오후 3 42 21 ...

Отзывы: