39
Temp Control &Operation Functions
No
Self Diagnosis
Error
Item
1
F-SENSOR
SENSOR HOUSING SLIP-OUT, CONTACT
DEFECT,WIRE CUT, WIRE SHORT,
SENSOR TEMP MORE THAN 122
℉
(+50
℃
) OR LOWER THAN 122
℉
(-50
℃
)
VOLTAGE BETWEEN MAIN PCB CN30
2
↔
3 SHALL BE WITHIN 4.5V~1.0V.
2
R-SENSOR
SENSOR HOUSING SLIP-OUT, CONTACT
DEFECT, WIRE CUT, WIRE SHORT,
SENSOR TEMP MORE THAN
122
℉
(+50
℃
)OR LOWER THAN 122
℉
(-50
℃
)
VOLTAGE BETWEEN MAIN PCB CN30
6
↔
7 SHALL BE WITHIN 4.5V~1.0V.
3
F-DEFROST
SENSOR
SENSOR HOUSING SLIP-OUT, CONTACT
DEFECT, WIRE CUT, WIRE SHORT,
SENSOR TEMP MORE THAN
122
℉
(+50
℃
)OR LOWER THAN 122
℉
(-50
℃
)
VOLTAGE BETWEEN MAIN PCB CN30
2
↔
4 SHALL BE WITHIN 4.5V~1.0V.
4
R-DEFROST
SENSOR
SENSOR HOUSING SLIP-OUT, CONTACT
DEFECT, WIRE CUT, WIRE SHORT,
SENSOR TEMP MORE THAN 122
℉
(+50
℃
)OR LOWER THAN 122
℉
(-50
℃
)
VOLTAGE BETWEEN MAIN PCB CN30
6
↔
8 SHALL BE WITHIN 4.5V~1.0V.
5
I/M-SENSOR
SENSOR HOUSING SLIP-OUT, CONTACT
DEFECT, WIRE CUT, WIRE SHORT,
SENSOR TEMP MORE THAN
122
℉
(+50
℃
)OR LOWER THAN 122
℉
(-50
℃
)
VOLTAGE BETWEEN MAIN PCB CN90
3
↔
4 SHALL BE WITHIN 4.5V~1.0V.
6
AMBIENT
SENSOR
SENSOR HOUSING SLIP-OUT, CONTACT
DEFECT, WIRE CUT, WIRE SHORT,
SENSOR TEMP MORE THAN
122
℉
(+50
℃
)OR LOWER THAN 122
℉
(-50
℃
)
VOLTAGE BETWEEN MAIN PCB CN31
1
↔
4 SHALL BE WITHIN 4.5V~1.0V.
7
F-DEFROST
ERROR
F-ROOM HEATER (SENSOR HOUSING SLIP-
OUT, CONTACT DEFECT, WIRE CUT, WIRE
SHORT OR TEMP FUSE DEFECT)
WHEN DEFROST DOES NOT FINISH EVEN
AFTER A 70-MINUTE CONTINUOUS
HEATING, IT DISPLAYS THE ERROR.
AFTER SEPARATING THE MAIN PCB CN70 WIRE FROM
PCB, CHECK THE RESISTANCE BETWEEN BROWN
↔
ORANGE. IT SHALL BE WITHIN ***OHM. (THE
RESISTANCE VARIES ACCORDING TO THE INPUT
POWER.) WHEN THE RESISTANCE IS 0 OHM,CHECK IF
THE HEATER IS SHORT AND WHEN IT IS
∞
OHM, CHECK
IF THE WIRE/TEMP FUSE IS OPEN
8
R-DEFROST
ERROR
R-ROOM HEATER (SENSOR HOUSING
SLIP-OUT, CONTACT DEFECT, WIRE CUT,
WIRE SHORT OR TEMP FUSE DEFECT)
WHEN DEFROST DOES NOT FINISH EVEN
AFTER A 80-MINUTE CONTINUOUS
HEATING, IT DISPLAYS THE ERROR.
AFTER SEPARATING THE MAIN PCB CN70 WIRE FROM
PCB,CHECK THE RESISTANCE BETWEEN WHITE
↔
ORANGE.IT SHALL BE WITHIN ***OHM. (THE
RESISTANCE VARIES ACCORDING TO THE INPUT
POWER.) WHEN THE RESISTANCE IS 0 OHM,CHECK IF
THE HEATER IS SHORT AND WHEN IT IS
∞
OHM,CHECK
IF THE WIRE/TEMP FUSE IS OPEN
9
I/M
FUNCTION
ERROR
MORE THAN 3 TIMES OF ICE MAKER
KIT ICE EJECTION OR HORIZONTAL
LEVELING ERROR
ONLY APPLIED TO MODEL WITH
ICE MAKER
10
Uart
Communication
Error (PLC)
- Descriptions for each Self Diagnosis Lamp
Communication error with PLC modem
Note) PLC Communication modem will be applied optionally.
So even if the appliance which does not apply PLC displays this error digit, It is not defect.
When it is not connected with PLC modem