- 5/39 -
Step 1
①
Check Tub for abnormal noise.
- Shake the Tub back and forth to check where the
noise is coming from.
②
Hanger Spring connection & Grease application
condition
- Check if grease is properly applied between
Hanger Spring and Hanger Guide friction part
.
Step 2
①
Check if Damper is separated or unassembled.
-
If the bolts connecting damper
- If the dampers are rusted or not fastening,
☞ replace.
②
Check the condition of loosening of Damper
connection.
- The shape of connected part of Bottom-Plate is
defective, and thus it does not rotate properly.
- It does not rotate properly because it was
connected too much in the assembling process.
☞ When it does not rotate properly, “Dda-dda-dda”
noise is generated due to friction between Damper &
Bottom-Plate. Thus, do as in ③.
③
What to do when Damper connection is
loosened.
- Add Nut M10.
- Product Name: Nut-Hexagon (6021-001588)
※ Damper connecting force : 250 ~ 350kgf.㎠
Check Point
Check the operating condition of Damper.
Tip 1-2. Damper & Hanger Abnormality