1. Precautions
1-1 Safety Precautions
1. Be sure that all of the built-in protective
devices are replaced. Restore any missing
protective shields.
2. When reinstalling the chassis and its
assemblies, be sure to restore all protective
devices, including: nonmetallic control knobs
and compartment covers.
3. Make sure that there are no cabinet openings
through which people—particularly
children—might insert fingers and contact
dangerous voltages. Such openings include
the spacing between the picture tube and the
cabinet mask, excessively wide cabinet
ventilation slots, and improperly fitted back
covers.
If the measured resistance is less than 1.0
megohm or greater than 5.2 megohms, an
abnormality exists that must be corrected
before the unit is returned to the customer.
4. Leakage Current Hot Check (Figure 1-1):
Warning: Do not use an isolation
transformer during this test. Use a leakage-
current tester or a metering system that
complies with American National Standards
Institute (ANIS C101.1, Leakage Current for
Appliances), and Underwriters Laboratories
(UL Publication UL1410, 59.7).
5. With the unit completely reassembled, plug
the AC line cord directly into the power
outlet. With the unit’s AC switch first in the
ON position and then OFF, measure the
current between a known earth ground (metal
water pipe, conduit, etc.) and all exposed
metal parts, including: antennas, handle
brackets, metal cabinets, screwheads and
control shafts. The current measured should
not exceed 0.5 milliamp. Reverse the power-
plug prongs in the AC outlet and repeat the
test.
Fig. 1-1 AC Leakage Test
6. Antenna Cold Check:
With the unit’s AC plug disconnected from the
AC source, connect an electrical jumper across
the two AC prongs. Connect one lead of the
ohmmeter to an AC prong. Connect the other
lead to the coaxial connector.
7. X-ray Limits:
The picture tube is especially designed to pro-
hibit X-ray emissions. To ensure continued
X-ray protection, replace the picture tube only
with one that is the same type as the original.
Carefully reinstall the picture tube shields and
mounting hardware; these also provide X-ray
protection.
8. High Voltage Limits:
High voltage must be measured each time ser-
vicing is done on the B+, horizontal deflection
or high voltage circuits. Correct operation of
the X-ray protection circuits must be
reconfirmed whenever they are serviced.
(X-ray protection circuits also may be called
“horizontal disable” or “hold-down”.)
Heed the high voltage limits. These include
the X–ray Protection Specifications Label, and
the Product Safety and X-ray Warning Note on
the service data schematic.
Precautions
Samsung Electronics
1-1
LEAKAGE
CURRENT
TESTER
DEVICE
UNDER
TEST
TEST ALL
EXPOSED METAL
SURFACES
2-WIRE CORD
ALSO TEST WITH
PLUG REVERSED
(USING AC ADAPTER
PLUG AS REQUIRED)
EARTH
GROUND
(READING SHOULD
NOT BE ABOVE
0.5mA)
Follow these safety, servicing and ESD precautions to prevent damage and protect against potential
hazards such as electrical shock and X-rays.
Содержание PCL 6215R
Страница 9: ...Reference Information 2 4 Samsung Electronics 2 3 IC Line Up 2 3 1 Progressive...
Страница 10: ...Reference Information Samsung Electronics 2 5...
Страница 11: ...Reference Information 2 6 Samsung Electronics 2 4 MICOM IIC BUS LINE UP...
Страница 30: ...Alignment and Adjustments 4 18 Samsung Electronics 4 7 3 473W 4715W NORMAL MODE 4 7 4 473W 4715W DTV MODE...
Страница 33: ...Alignment and Adjustments Samsung Electronics 4 21 4 7 9 6215R NORMAL MODE 4 7 10 6215R DTV MODE...
Страница 35: ...Alignment and Adjustments Samsung Electronics 4 23 4 8 Remote Control for Servicing Convergence Mode...
Страница 131: ...7 76 Samsung Electronics MEMO...
Страница 140: ...TP02 TP01 10 Schematic Diagrams Samsung Electronics Schematic Diagrams 10 1 10 1 MAIN 1 TP01 TP02...
Страница 141: ...Schematic Diagrams 10 2 Samsung Electronics TP20 TP03 TP04 10 2 MAIN 2 TP03 TP04 TP20...
Страница 142: ...Samsung Electronics Schematic Diagrams 10 3 10 3 MAIN 3 TP12 TP13 TP12 TP13...
Страница 144: ...Samsung Electronics Schematic Diagrams 10 5 10 5 MICOM...
Страница 145: ...Schematic Diagrams 10 6 Samsung Electronics 10 6 CRT...
Страница 146: ...Samsung Electronics Schematic Diagrams 10 7 10 7 SUB 1 TP21 TP21...
Страница 147: ...Schematic Diagrams 10 8 Samsung Electronics 10 8 SUB 2 TP24 TP23 TP22 TP22 TP23 TP24...
Страница 148: ...Samsung Electronics Schematic Diagrams 10 9 10 9 CONVERGENCE SDC12 1...
Страница 149: ...Schematic Diagrams 10 10 Samsung Electronics 10 10 CONVERGENCE SDC12 2...
Страница 150: ...Samsung Electronics Schematic Diagrams 10 11 10 11 PRO SCAN 1...
Страница 151: ...Schematic Diagrams 10 12 Samsung Electronics 10 12 PRO SCAN 2...
Страница 152: ...Samsung Electronics Schematic Diagrams 10 13 10 13 PRO SCAN 3...
Страница 153: ...Schematic Diagrams 10 14 Samsung Electronics 10 14 PRO SCAN 4...
Страница 154: ...10 15 CG AMP Samsung Electronics Schematic Diagrams 10 15...
Страница 155: ...Schematic Diagrams 10 16 Samsung Electronics 10 16 AV FRONT...
Страница 156: ...10 17 CONTROL Samsung Electronics Schematic Diagrams 10 17...
Страница 157: ...Schematic Diagrams 10 18 Samsung Electronics 10 18 DY JACK SENSOR DY JACK SENSOR...