23
10. Designation of Main Components
10-1 Normal / Reverse Revolution of Motor and R. P. M. Control
10-2 Door safety Device
1)Capacity
Code No : DC64-00652A
3P 1 - 2 Locking
: 135
Ω
±10%
2 - 3 UnLocking : 135
Ω
±10%
4P 1 - 2 Door Lock 250V 16A
3 - 4 Door close 250V (16)1A
+
-
8
9
5
10
Rotor
Stator coil
CW
+
-
8
9
5
5
10
Rotor
Stator coil
CCW
<Figure1>
<Figure2>
1 2 3 4 5 6 7 8 9 10
STATOR
WASHING MOTOR
T
A
C
H
O
H
IG
H
-S
P
E
E
D
S
T
A
T
O
R
P
R
O
T
E
C
T
O
R
M
ID
D
L
E
-S
P
E
E
D
R
O
T
O
R
(1
50
C
)
H
(
± 7%)
STATOR(51) ROTOR(8.9) TACHO(3.4) PROTECTOR(6.7) "H"(mm)
Code-No.
Remark
Resistance
value
2.08
Ω
1.99
Ω
38.8
Ω
0
39
DC31-00002E
C1235
Rated
value
220~240V/50Hz
Содержание P1001
Страница 4: ...2 Overview of the Washing Machine 4 SAMSUNG ELECTRONICS CO LTD ...
Страница 14: ...12 SAMSUNG ELECTRONICS CO LTD 8 PCB Schematic Diagram ...
Страница 15: ...8 PCB CIRCUIT DIAGRAM SAMSUNG ELECTRONICS CO LTD ...
Страница 23: ...SAMSUNG ELECTRONICS CO LTD 17 11 WC TOP FRONT Exploded View ...
Страница 25: ...19 SAMSUNG ELECTRONICS CO LTD 12 WD TUB Exploded View ...
Страница 29: ...15 TOP FRONT Exploded View R0019 R0036 A0242 F0125 F0064 C0103 D0112 D0061 D0045 D0004 C0002 C0115 R0036 ...
Страница 35: ...ELECTRONICS Samsung Electronics Co Ltd May 2000 Printed in Korea Code No DC68 00799A ...