OH85N/(LH85OHNSLGB/**)
Double-sided enclosure unit
Design the enclosure unit to keep discharged hot air from flowing back into the inlet.
•
Clearance ( ): 400 mm or more
•
Air inlet ( + + )
Total open area of the ventilation holes: 126000
mm or more
Ventilation opening ratio (% of total opening): 70 % or more
•
Air outlet ( + )
Total open area of the ventilation holes: 126000
mm or more
Ventilation opening ratio (% of total opening): 70 % or more
–
When designing double-sided enclosure units, position the inlet on the top or side.
–
Outlets of the enclosure unit should be on the side.
•
Add partitions without any gap (as shown in the image below) to completely separate the inlet and outlet.
–
Secure at least 400 mm of clearance between two products.
At least 400 mm of
clearance between products
Partition
Partition
To add devices such as a media player
If installing other devices such as a media player, use partitions to make sure they are installed separately from the
product.
–
Heat from other devices can increase the temperature inside the enclosure unit and cause a malfunction, which will
not be covered by the warranty.
–
Design to make sure there is no gap around the partitions due to cable connections.