background image

OHN
OH85N/(LH85OHNSKGB/**)
OH85N-D(K)/(LH85OHNDKGB/**)
OH85N/(LH85OHNSLGB/**)

Follow the instructions provided in this guide when installing the product.
Samsung will not provide warranty coverage for problems that may arise as a result of failure to follow the guide.
The color and shape of the product may vary. In addition, instructions in the installation guide may change without prior notice when 

necessary to improve the product.

Outdoor 

Installation Guide

Содержание OH85N

Страница 1: ...alling the product Samsung will not provide warranty coverage forproblems that may arise as a result of failure to follow the guide The colorand shape of the product mayvary In addition instructions in the installation guide may change without priornotice when necessary to improve the product Outdoor Installation Guide ...

Страница 2: ...l mount 11 02 Enclosureunitdesignguide Air flow direction 12 Inlet and outlet types 12 Total open area of the ventilation holes and ratio 13 Precautions for enclosure unit designing 13 Enclosure unit partition design 14 Single enclosure unit 14 1 x N one side unit design 15 Double sided design 15 To add devices such as a media player 15 03 Handlingguide Moving by crane 16 04 Cleaningandcautions Cl...

Страница 3: ...lt angle 27 Clearance for installation 28 02 Enclosureunitdesignguide Air flow direction 29 Inlet and outlet types 29 Total open area of the ventilation holes and ratio 30 Precautions for enclosure unit designing 30 Single enclosure unit 31 1 x N one side unit design 31 03 Handlingguide Moving by crane 32 04 Cleaningandcautions Cleaning 33 Precautions 35 ...

Страница 4: ...Air flow direction 46 Inlet and outlet types 46 Total open area of the ventilation holes and ratio 47 Precautions for enclosure unit designing 47 Enclosure unit partition design 48 Single enclosure unit 48 1 x N one side unit design 49 Double sided enclosure unit 50 To add devices such as a media player 50 03 Handlingguide Moving by crane 51 04 Cleaningandcautions Cleaning 52 Precautions 54 ...

Страница 5: ...KGB OH85N LH85OHNSKGB ...

Страница 6: ...n block off at least 50 of the solarheat the unit receives Installingtheprotectionglass Samsung guarantees the product swaterand dust resistance performance IP56 This guarantee however does not coveranyissues resulted from the choice of non recommended protection glass orinstallation method Examples Issues caused bythe ingress of dust orhumidityfrom outside ordue to insufficient insulation against...

Страница 7: ...et maycause a malfunction The product can be used in a train orsubway station The product is designed to keep out iron dust When installed in beach area make sure the display is placedwhere seawatercannot reach Ensure the displayunit installed location iswithin safe distance from the possible contact from rising seawaterdue to strongwinds due to storm orother natural phenomenon The guide forOH85N ...

Страница 8: ...l oran obstacle up to15 Contact Samsung CustomerService Centerforfurtherdetails 15 Θ Wall or obstacle Wall or obstacle 50 mm ormore 50 mm ormore Landscape Portrait Do not use this model installed on a ceiling floor ortable The guide forOH85N LH85OHNSKGB onlyapplieswhen the product is usedwith an enclosure unit that has a protective glass added to the front side English 8 ...

Страница 9: ...eat due to an insufficient gap this maycause a malfunction whichwill not be covered bythewarranty Sideview Wall orobstacle Partition Clearanceforbuilt ininstallation When installing built in to thewall maintain the clearance from the back top bottom and sides of the product in orderto secure airflow Clearance from thewall Example1 Atmospheric temperatures under35 without direct sunlight 60 mm ormo...

Страница 10: ...an obstacle orawall maycause a malfunction ora problemwith the product Clearance 200 mm ormore Remove anyobstacles nearthe inlet and outlet that mayaffect airflow If the unit is subjected to excess heat due to an insufficient gap this maycause a malfunction whichwill not be covered bythewarranty Sideview Wall orobstacle Partition Partition The guide forOH85N LH85OHNSKGB onlyapplieswhen the product...

Страница 11: ...de holes Mount holes 15 mm Mount hole M8 bolt Portraitinstallation Do not use the 4 holes at the bottom as theyare NOTmount holes Use M8 bolts in the 8 holes formounting 4 at the top and 4 in the center Choose the length based on the mount thickness The mount hole depth forthis product is15 mm except the mount Use the M8 bolts that can be fastened into at least 10 mm out of the15 mm holes afterpas...

Страница 12: ... discharge the hot air When installing the product remove anyobstacles nearthe airinlet and outlet that mayaffect airflow Back Sideview Airinlet Airoutlet Inletandoutlettypes Ventilation opening ratio forairinlet and outlet should be minimum 70 Airinlet and outlet should be grid ormesh types Do not use the louvertype as it has a limited intake size Grid type Mesh type Louvertype The guide forOH85N...

Страница 13: ...9 mm Total open area ofVentilation holes 20 x 20 x 32 12 800 mm 181 mm 3 mm 20 mm 89 mm Ventilation opening ratio Total open area ofVentilation holes 12 800 mm x100 79 Total Area of theVentilation 16 109 mm Precautionsforenclosureunitdesigning Considerthe location of the IR Remote and Eco Sensoronyourproductwhen designing an enclosure unit The sensormaynotwork orcause the screen to darken if the s...

Страница 14: ... specifications to keep discharged hot airfrom flowing back into the inlet Airinlet Total open area of theventilation holes 63000 mm ormore Ventilation opening ratio of total opening 70 ormore Airoutlet Total open area of theventilation holes 63000 mm ormore Ventilation opening ratio of total opening 70 ormore Design the locations of the enclosure unit inlet and outlet to match the locations of th...

Страница 15: ...Double sided design is not supported Toadddevicessuchasamediaplayer If installing otherdevices such as a media player use partitions to make sure theyare installed separatelyfrom the product Heat from otherdevices can increase the temperature inside the enclosure unit and cause a malfunction whichwill not be covered bythewarranty Design to make sure there is no gap around the partitions due to cab...

Страница 16: ... Use the crane to move the product Landscape Portrait 3 When the product has been brought to the installation site unfasten and remove the Bracket Hang and bolts 4 Place Cover Caps in the holes on the top and sides Cover Caps foryourproduct are found enclosed in the package The guide forOH85N LH85OHNSKGB onlyapplieswhen the product is usedwith an enclosure unit that has a protective glass added to...

Страница 17: ...eaning Cleaningtheprotectionglass Consult the manufacturerof the protective glass forcleaning The guide forOH85N LH85OHNSKGB onlyapplieswhen the product is usedwith an enclosure unit that has a protective glass added to the front side English 17 ...

Страница 18: ...r keep the pressure below0 5 bar Check once every6 months and clean the inlet and outlet if theyare covered blocked bydust and othermaterials more than 20 Remove powerbefore cleaning Use an industrial gradevacuum cleaner vacuum degree 2600 3000 mm H20 Back Front The guide forOH85N LH85OHNSKGB onlyapplieswhen the product is usedwith an enclosure unit that has a protective glass added to the front s...

Страница 19: ...routingcables Route cables connected to the product in a mannerthat keeps them awayfromwater The guide forOH85N LH85OHNSKGB onlyapplieswhen the product is usedwith an enclosure unit that has a protective glass added to the front side English 19 ...

Страница 20: ...reach 7 Ø x1 Insert the 7 Ø cable 5 5 Ø x 6 Insert the 5 5 Ø cable 3 Ø x 2 Insert the 3 Ø cable 8 5 Ø x1 Insert the 8 5 Ø cable Insert the appropriate cable into the hole fromwhich the silicone barwas removed The cable should be connected as shown Close the cover then fasten the screws Afterall the cables are connected make sure to close the coverand fasten the screws to ensure it iswatertight Rec...

Страница 21: ...en the screws Differentpowercablecolorsbycountry When connecting an external powercable be sure to match the colors of itswireswith those of the 3wires inside the product s powercable The meaning Neutral Live orGround of eachwire colorof the external powercable maydiffer depending on the country Be sure to referto the following table to correctlyconnectwires bythe same meaning Neutral Live Ground ...

Страница 22: ...n Thiswill lessen the protection ofyourproduct against waterand mayresult in a malfunction due towaterdamage whichwill not be covered bythewarranty Silicone bar Aftercomplete cabling ensure that there is no gap between the set panel and the coverterminal A gap mayallowwaterdamage and product malfunction Coverterminal Set panel The guide forOH85N LH85OHNSKGB onlyapplieswhen the product is usedwith ...

Страница 23: ...autionswhenreplacingparts This product is designed to resistwaterand dust Do not disassemble the product If disassemblyis necessarydue to a malfunction contact the service center The guide forOH85N LH85OHNSKGB onlyapplieswhen the product is usedwith an enclosure unit that has a protective glass added to the front side English 23 ...

Страница 24: ...OH85N D K LH85OHNDKGB ...

Страница 25: ... glass that can block off at least 50 of the solarheat the unit receives Installingtheprotectionglass Samsung guarantees the product swaterand dust resistance performance IP56 This guarantee however does not coveranyissues resulted from the choice of non recommended protection glass orinstallation method Examples Issues caused bythe ingress of dust orhumidityfrom outside ordue to insufficient insu...

Страница 26: ...ing the inlet oroutlet maycause a malfunction The product can be used in a train orsubway station The product is designed to keep out iron dust When installed in beach area make sure the display is placedwhere seawatercannot reach Ensure the displayunit installed location iswithin safe distance from the possible contact from rising seawaterdue to strongwinds due to storm orother natural phenomenon...

Страница 27: ...dscape Contact Samsung CustomerService Centerforfurtherdetails Θ Wall or obstacle 50 mm ormore Portrait Do not use this model installed on a ceiling floor ortable The guide forOH85N D K LH85OHNDKGB onlyapplieswhen the product is usedwith an enclosure that has a protective glass added to the front side English 27 ...

Страница 28: ...f the unit is subjected to excess heat due to an insufficient gap this maycause a malfunction whichwill not be covered bythewarranty 250 mm ormore 200 mm ormore Floor Hingeinstallationguide Referto the image belowwhen installing the Hinge Use sets of 6 dedicated M8 bolts forHinge installation To purchase the Hinge and M8 bolts M8 x L23 contactyourproviderorSamsung 5 mm 7 mm The guide forOH85N D K ...

Страница 29: ...perature and discharge the hot air When installing the product remove anyobstacles nearthe airinlet and outlet that mayaffect airflow Label rating Inletandoutlettypes Ventilation opening ratio forairinlet and outlet should be minimum 70 Airinlet and outlet should be grid ormesh types Do not use the louvertype as it has a limited intake size Grid type Mesh type Louvertype The guide forOH85N D K LH8...

Страница 30: ...109 mm Total open area ofVentilation holes 20 x 20 x 32 12 800 mm 181 mm 3 mm 20 mm 89 mm Ventilation opening ratio Total open area ofVentilation holes 12 800 mm x100 79 Total Area of theVentilation 16 109 mm Precautionsforenclosureunitdesigning Considerthe location of the IR Remote and Eco Sensoronyourproductwhen designing an enclosure unit The sensormaynotwork orcause the screen to darken if the...

Страница 31: ...t Open area of EnclosureVentilation holes 80 000 mm ormore Ventilation opening ratio of total opening 70 ormore Design the locations of the enclosure unit inlet and outlet to match the locations of the product inlet and outlet 1xNone sideunitdesign Referto the Total open area of theventilation holes and ratio Page 30 Product 2 Product1 Product 3 The guide forOH85N D K LH85OHNDKGB onlyapplieswhen t...

Страница 32: ...e Bracket Hang and bolts M8 x L23 contactyourproviderorSamsung 2 Use the crane to move the product Portrait 3 When the product has been brought to the installation site unfasten and remove the Bracket Hang and bolts The guide forOH85N D K LH85OHNDKGB onlyapplieswhen the product is usedwith an enclosure that has a protective glass added to the front side English 32 ...

Страница 33: ...Cleaning Cleaningtheprotectionglass Consult the manufacturerof the protective glass forcleaning The guide forOH85N D K LH85OHNDKGB onlyapplieswhen the product is usedwith an enclosure that has a protective glass added to the front side English 33 ...

Страница 34: ...withwater keep the pressure below0 5 bar Check once every6 months and clean the inlet and outlet if theyare covered blocked bydust and othermaterials more than 20 Remove powerbefore cleaning Use an industrial gradevacuum cleaner vacuum degree 2600 3000 mm H20 The guide forOH85N D K LH85OHNDKGB onlyapplieswhen the product is usedwith an enclosure that has a protective glass added to the front side ...

Страница 35: ... cables connected to the product in a mannerthat keeps them awayfromwater Route cables awayfrom the inlet and outlet The guide forOH85N D K LH85OHNDKGB onlyapplieswhen the product is usedwith an enclosure that has a protective glass added to the front side English 35 ...

Страница 36: ... the main display Silicone bar Remove the appropriate silicone barforthe thickness of the cable to connect Insert the appropriate cable into the hole fromwhich the silicone barwas removed Once all cables are connected place the cable staple back to the bottom of the main display Close the auxiliarydisplay completely then fasten the brackets on both sides of the product The guide forOH85N D K LH85O...

Страница 37: ...tom of the main display Close the auxiliarydisplay completely then fasten the brackets on both sides of the product Differentpowercablecolorsbycountry When connecting an external powercable be sure to match the colors of itswireswith those of the 3wires inside the product s powercable The meaning Neutral Live orGround of eachwire colorof the external powercable maydiffer depending on the country B...

Страница 38: ... Ø cables 5 5 Ø hole Forinserting 5 5 6 Ø cables 3 Ø hole Forinserting 3 3 5 Ø cables Do not remove silicon barswhere there is no cable connection Thiswill lessen the protection ofyourproduct against waterand mayresult in a malfunction due towaterdamage whichwill not be covered bythewarranty Silicone bar The guide forOH85N D K LH85OHNDKGB onlyapplieswhen the product is usedwith an enclosure that h...

Страница 39: ...o resistwaterand dust Do not disassemble the product If disassemblyis necessarydue to a malfunction contact the service center The guide forOH85N D K LH85OHNDKGB onlyapplieswhen the product is usedwith an enclosure that has a protective glass added to the front side English 39 ...

Страница 40: ...OH85N LH85OHNSLGB ...

Страница 41: ...et Blockedventilation due to snowordust covering the inlet oroutlet maycause a malfunction The product can be used in a train orsubway station The product is designed to keep out iron dust When installed in beach area make sure the display is placedwhere seawatercannot reach Ensure the displayunit installed location iswithin safe distance from the possible contact from rising seawaterdue to strong...

Страница 42: ...ons This product can be installed in a tilted position on averticalwall oran obstacle up to15 Contact Samsung CustomerService Centerforfurtherdetails 15 Θ Wall or obstacle Wall or obstacle 50 mm ormore 50 mm ormore Landscape Portrait Do not use this model installed on a ceiling floor ortable English 42 ...

Страница 43: ...eat due to an insufficient gap this maycause a malfunction whichwill not be covered bythewarranty Sideview Wall orobstacle Partition Clearanceforbuilt ininstallation When installing built in to thewall maintain the clearance from the back top bottom and sides of the product in orderto secure airflow Clearance from thewall Example1 Atmospheric temperatures under35 without direct sunlight 60 mm ormo...

Страница 44: ...ng the product Excessive heat due to the use of the enclosure unitwith an obstacle orawall maycause a malfunction ora problemwith the product Clearance 200 mm ormore Remove anyobstacles nearthe inlet and outlet that mayaffect airflow If the unit is subjected to excess heat due to an insufficient gap this maycause a malfunction whichwill not be covered bythewarranty Sideview Wall orobstacle Partiti...

Страница 45: ...5 mm holes afterpassing through the mount M8 bolts are not included Guide holes Mount holes 15 mm Mount hole M8 bolt Portraitinstallation Do not use the 4 holes at the bottom as theyare NOTmount holes Use M8 bolts in the 8 holes formounting 4 at the top and 4 in the center Choose the length based on the mount thickness The mount hole depth forthis product is15 mm except the mount Use the M8 bolts ...

Страница 46: ...ooling fans to take in outside airto lowerthe internal temperature and discharge the hot air When installing the product remove anyobstacles nearthe airinlet and outlet that mayaffect airflow Back Sideview Airinlet Airoutlet Inletandoutlettypes Ventilation opening ratio forairinlet and outlet should be minimum 70 Airinlet and outlet should be grid ormesh types Do not use the louvertype as it has a...

Страница 47: ...dVentilation opening ratio Total Area of theVentilation 181 x 89 16 109 mm Total open area ofVentilation holes 20 x 20 x 32 12 800 mm 181 mm 3 mm 20 mm 89 mm Ventilation opening ratio Total open area ofVentilation holes 12 800 mm x100 79 Total Area of theVentilation 16 109 mm Precautionsforenclosureunitdesigning Considerthe location of the IR Remote and Eco Sensoronyourproductwhen designing an enc...

Страница 48: ...ngleenclosureunit Design the enclosure unit according to the following specifications to keep discharged hot airfrom flowing back into the inlet Airinlet Total open area of theventilation holes 63000 mm ormore Ventilation opening ratio of total opening 70 ormore Airoutlet Total open area of theventilation holes 63000 mm ormore Ventilation opening ratio of total opening 70 ormore Design the locatio...

Страница 49: ...osure unit add partitions between the products to keep the airpaths separated Referto the Total open area of theventilation holes and ratio Page 47 Make sure there is no gap between the partitions and the enclosure unit Product 2 Partition Partition Product1 Product 3 English 49 ...

Страница 50: ...rside Outlets of the enclosure unit should be on the side Add partitionswithout anygap as shown in the image below to completelyseparate the inlet and outlet Secure at least 400 mm of clearance between two products At least 400 mm of clearance between products Partition Partition Toadddevicessuchasamediaplayer If installing otherdevices such as a media player use partitions to make sure theyare in...

Страница 51: ...hase the Bracket Hang and bolts M8 x L23 contactyourproviderorSamsung 2 Use the crane to move the product Landscape Portrait 3 When the product has been brought to the installation site unfasten and remove the Bracket Hang and bolts 4 Place Cover Caps in the holes on the top and sides Cover Caps foryourproduct are found enclosed in the package English 51 ...

Страница 52: ...loth dampenedwithwatertowipe off the surface Magic Glass Wipe off the surface periodicallywith a clean soft cloth dampenedwithwaterorglass cleaner cleaning cycle within1 month Fordirt that cannot be removed use an ethanol based cleaner Aftera rain use a clean soft cloth towipe off rain drops ordirts from the glass English 52 ...

Страница 53: ...g a clothwith a small amount of ethanol based cleaner Ifwashingwithwater keep the pressure below0 5 bar Check once every6 months and clean the inlet and outlet if theyare covered blocked bydust and othermaterials more than 20 Remove powerbefore cleaning Use an industrial gradevacuum cleaner vacuum degree 2600 3000 mm H20 Back Front English 53 ...

Страница 54: ...ardingtheCover Cap Place Cover Caps in the holes on the top and sides Cover Caps foryourproduct are found enclosed in the package Cautionswhenroutingcables Route cables connected to the product in a mannerthat keeps them awayfromwater English 54 ...

Страница 55: ...e to connect Different hole sizes and corresponding cable thickness foreach 7 Ø x1 Insert the 7 Ø cable 5 5 Ø x 6 Insert the 5 5 Ø cable 3 Ø x 2 Insert the 3 Ø cable 8 5 Ø x1 Insert the 8 5 Ø cable Insert the appropriate cable into the hole fromwhich the silicone barwas removed The cable should be connected as shown Close the cover then fasten the screws Afterall the cables are connected make sure...

Страница 56: ...cted part of the cable inside the product Place the back coverand fasten the screws Differentpowercablecolorsbycountry When connecting an external powercable be sure to match the colors of itswireswith those of the 3wires inside the product s powercable The meaning Neutral Live orGround of eachwire colorof the external powercable maydiffer depending on the country Be sure to referto the following ...

Страница 57: ...5 Ø cables Do not remove silicon barswhere there is no cable connection Thiswill lessen the protection ofyourproduct against waterand mayresult in a malfunction due towaterdamage whichwill not be covered bythewarranty Silicone bar Aftercomplete cabling ensure that there is no gap between the set panel and the coverterminal A gap mayallowwaterdamage and product malfunction Coverterminal Set panel E...

Страница 58: ...ure to close the coverand fasten the screws to ensure it iswatertight Cautionswhenreplacingparts This product is designed to resistwaterand dust Do not disassemble the product If disassemblyis necessarydue to a malfunction contact the service center English 58 ...

Страница 59: ...Thispageisintentionally leftblank ...

Страница 60: ...Thispageisintentionally leftblank ...

Отзывы: