English 17
Ins
tallation r
equir
ement
s
Gas requirements
Provide adequate gas supply
This range is designed to operate at a pressure of 5 in (13 cm) of water column on
natural gas or 10 in (25 cm) of water column on LP gas (propane or butane).
Make sure you are supplying your range with the type of gas for which it is
designed.
Do not attempt to convert the appliance from the gas specified in this
manual to a different gas without consulting the gas supplier.
This range is convertible for use on natural or propane gas. If you decide to use
this range on LP gas, conversion must be made by a qualified LP installer before
attempting to operate the range.
For proper operation, the pressure of natural gas supplied to the regulator must be
between 5 in and 13 in (13 cm and 33 cm) of water column.
For LP gas, the pressure supplied must be between 10 in and 13 in (25 cm and
33 cm) of water column.
When checking for proper operation of the regulator, the inlet pressure must be at
least 1 in (2.5 cm) greater than the operating (manifold) pressure as given.
The pressure regulator located at the inlet of the range manifold must remain in
the supply line regardless of whether natural or LP gas is being used.
A flexible-metal appliance connector used to connect the range to the gas supply
line should have an I.D. of 0.5 in (1.3 cm) and be 5 ft (152 cm) in length for ease of
installation. In Canada, flexible connectors must be single-wall metal connectors no
longer than 6 ft (183 cm) in length.
Do not kink or damage the flexible metal tubing when moving the range.
Special gas requirements (gas models sold in massachusetts)
COMMONWEALTH OF MASSACHUSETTS REQUIREMENTS:
WARNING
Gas leaks may occur in your system, creating a dangerous situation.
– Gas leaks may not be detected by smell alone.
– Gas suppliers recommend you purchase and install a UL-approved gas detector.
Gas detector should be installed in accordance with the manufacturers
instructions.
•
Range must be installed by a qualified plumber or gas fitter by the State of
Massachusetts.
•
A T-handle manual gas valve MUST be installed in the gas supply line to your
range.
•
If a flexible gas connector is used to install your range, multiple flexible gas lines
must not be connected in series.
Electrical requirements
WARNING
To reduce the risk of fire, electric shock, or personal injury:
All ranges
•
Do not use an extension cord or adapter plug with this range.
•
This range must be properly grounded.
•
Check with a qualified electrician if you are in doubt as to whether your range is
properly grounded.
•
Do not modify the plug provided with your range—if it doesn’t fit the outlet, have
a proper outlet installed by a qualified electrician.
•
All wiring and grounding must be done in accordance with local codes or, in the
absence of local codes, with the National Electrical Code, ANSI/NFPA No. 70 –
Latest Revision (for the U.S.) or the Canadian Electrical Code CSA C22.1 – Latest
Revisions and local codes and ordinances.
•
Wiring diagram is located on the back of the range. (Inside of the cover back wire)
•
This range is equipped with an electronic ignition system that will not operate if
plugged into an outlet that is not properly polarized.
Install_NX58M9420SS_DG68-00906A-00_EN.indd 17
1/6/2017 6:25:51 PM
Содержание NX58M9420SS Series
Страница 26: ...Memo Install_NX58M9420SS_DG68 00906A 00_EN indd 26 1 6 2017 6 25 55 PM ...
Страница 27: ...Memo Install_NX58M9420SS_DG68 00906A 00_EN indd 27 1 6 2017 6 25 55 PM ...
Страница 54: ...Notas Install_NX58M9420SS_DG68 00906A 00_MES indd 26 1 6 2017 6 23 04 PM ...
Страница 55: ...Notas Install_NX58M9420SS_DG68 00906A 00_MES indd 27 1 6 2017 6 23 04 PM ...
Страница 82: ...Notes Install_NX58M9420SS_DG68 00906A 00_CFR indd 26 1 6 2017 6 25 17 PM ...
Страница 83: ...Notes Install_NX58M9420SS_DG68 00906A 00_CFR indd 27 1 6 2017 6 25 17 PM ...