Flexible connector hookup
Installer: Inform the consumer of the location of the gas shut-off valve.
If your area requires a rigid pipe
hookup, contact a qualified
installer, service agency, or gas
supplier.
The gas shut-off valve should
be installed in an accessible
location in the gas piping,
external to the appliance, for the
purpose of turning on or shutting
off the gas to the appliance.
Step 3. Convert to lp gas (optional)
All new gas ranges are shipped from the factory set up to use natural gas. Any
Samsung gas range can be converted to use LP gas. Refer to page 78 in the
User Manual to contact a qualified service technician.
The conversion process should only be performed by a qualified LP gas installer.
Conversion instructions and LP orifices will be supplied with the LP conversion
kit. The conversion to LP requires all burner orifices to be changed (5 surface
burners and 2 oven burners).
In addition, the nozzle on the gas pressure regulator needs to be reversed. All
replaced orifices must be left with the consumer, including the instructions and
retrofit sizes and orifice indication.
BURNER ORIFICE SIZES AND
OUTPUT RATINGS
(LP Gas [Propane] 10 in WCP)
BURNER ORIFICE SIZES AND
OUTPUT RATINGS
(Natural Gas 5 in WCP)
Burner
Location
BTU Rate
Orifice Size
[mm]
Burner
location
BTU Rate
Orifice size
[mm]
RF¹
14500
1.12
RF¹
18000
1.92
RF²
12500
1.06
RF²
17000
1.92
LF¹
11500
1.04
LF
15000
1.78
LF²
10000
0.98
RR
5000
1.01
RR
4000
0.62
LR
9500
1.40
LR
7500
0.83
CTR
9500
1.38
CTR
7500
0.83
BAKE
18000
1.90
BAKE
15000
1.15
BROIL
13500
1.64
BROIL
11500
1.02
¹
Model NX58H5650W*
²
Model NX58H5600S*, NX58J5600S*, NX58M5600S*
Pressure
Regulator
Adapter
Flex Connector
(6-ft max.)
Adapter
Gas Shut-Off Valve
0.5-in or 0.75-in Gas Pipe
Tubing Line to
Oven Burner
Control Valve
Tubing Line
to Cooktop
Control
Manifold
Gas Flow int
o Range