4- 18
4.
Troubleshooting
6) CPU Fan Control
1) Fan Operation Analysis
- One can turn the fan on & off and check the fan's operational conditions without
system disassembly
Figure (1) Fan off
Figure (2) Fan on
- SAFC's default setting is "Fan off" or "Minimum Fan Speed".
- Press "ON" in "ON/OFF Control" Fan is turned on to maximum fan speed.
- Press "OFF" in "ON/OFF Control" Fan returns to default setting.
2) Fan RPM Pass level.
No
Item
Mode
rpm Design guideline
SPEC : ± 10%
1
FAN Voltage
Off
0
IDLE
1800 rpm
LOW
2200 rpm
MID
2600 rpm
HIGH
3000 rpm
1단계
2단계
3단계
4단계
Figure (3) Fan Step Control
> Fan Voltage Measurement
- Read Fan RPM indicated in SAFC.
> Fan Voltage Pass/Fail determination
- If Fan RPM satisfies "rpm spec +/-10%", then Fan test is "PASS" .
- This Document can not be used without Samsung's authorization -
Fan rpm : 1800 rpm
SAFC will be upgraded to
include Fan RPM
1st step
2nd step
3rd step
4th step
Содержание NT-R70xxxx Series
Страница 3: ......
Страница 4: ......
Страница 5: ......
Страница 6: ......
Страница 7: ...Решение ...
Страница 8: ...R70 R40 ...
Страница 9: ...Относится к моделям произведенным в июле августе 2007 года ...
Страница 10: ......
Страница 11: ...В модели R60 может использоваться память нового производителя A DATA part number 1105 001797 ...
Страница 28: ...2 15 2 Introduction and Specification This Document can not be used without Samsung s authorization ...
Страница 29: ...2 16 2 Introduction and Specification This Document can not be used without Samsung s authorization ...
Страница 141: ...4 20 4 Troubleshooting This document cannot be used without the authorization of Samsung ...
Страница 142: ...4 21 4 Troubleshooting This document cannot be used without the authorization of Samsung ...