Samsung NS026NHXEA Скачать руководство пользователя страница 3

E-

3

ENGLISH

  You must install the product by qualified installer. If you install the product on your own or by unqualified 

person, Samsung is not responsible for any damages which may occur due to incorrect installation.

  Make sure to read the following safety precautions carefully before installation.

  Make sure to observe the cautions specified in this manual.

  Conduct a test run of the unit after installation and then explain all system functions to the owner.

  The indications and meanings are as shown below.

WARNING 

 

Hazards or unsafe practices that may result in 

severe personal injury or death.

Installation must be carried 

out by a qualified installer. 

Do not attempt to repair, 

move, modify or reinstall the 

unit on your own since such 

act may cause fire, electric 

shock or water leakage.

Install the unit in a place 

where it is strong enough 

to hold the product weight. 

When installed in place 

where it is not strong enough 

to withhold the product 

weight, the unit could fall 

and cause injury.

The unit should be 

installed in accordance 

with the National Electrical 

regulations. Check if the 

voltage and the frequency of 

the main power supply are 

those required for the unit 

to be installed and check the 

connection. Avoid the use of 

an extension cord and do not 

share the power outlet with 

other appliances. Incomplete 

connection, defective 

insulation or exceeding the 

permissible current may 

cause electric shock or fire.

Use the specified wires to 

connect the indoor and 

outdoor units securely and 

attach the wires firmly to the 

terminal block connecting 

sections so that the pressure 

is not applied to the sections. 

Inappropriate connection 

and fixing could cause fire.

Attach the electrical cover to 

the indoor and outdoor unit 

securely without any gaps.

If there are any gaps, there is 

potential risk of fire or electric 

shock due to dust or water.

Make sure to use the part 

provided or specified parts for 

the installation work. The use 

of defective parts could cause 

an injury or leakage of water 

due to a fire, an electric shock, 

the unit falling, etc.

Make sure that the 

refrigerant gas does not 

leak after completing the 

installation.

If the refrigerant gas of 

the indoor unit leaks and 

comes into contact with the 

fan heater, space heater or 

stove, harmful gas will be 

generated.

Ensure that the national 

safety code requirements 

have been followed for the 

main supply circuit. Ensure 

that a proper ground wire is 

in place.

Do not connect the ground 

to a gas pipe, water pipe, 

lightning rod or telephone 

grounding. Defective 

grounding could cause 

electric shock.

Do not install the unit in a 

place with direct sunlight, 

dangerous substances 

or where it is exposed to 

inflammable gas leakage 

to prevent explosion, fire or 

personal injury.

Perform the installation 

securely referring to 

the installation manual. 

Incomplete installation 

could cause personal injury 

due to fire, electric shock 

and water leakage or from 

the unit falling.

Before connecting the 

power plug and power 

receptacle check for dust, 

loose or blocked. Make sure 

that plug is fully inserted.

Dusted power plug, 

blocked or loosened power 

receptacle may cause fire 

or electric shock. Exchange 

the power receptacle if it is 

loose.

Check first the following 

situations before starting 

the operation during the 

installation.

-  The pipe must be properly 

connected and make sure 

there is no leakage.

-  Service valves must be open. 

If compressor is operated 

with the service valve 

closed, excessive pressure 

may damage parts of the 

compressor. 

If leakage occurs on any of 

the connection, air inflow 

may also cause excessive 

pressure that could lead to 

explosion.

Safety Precautions

  Keep this installation manual together with the user’s manual in a handy place so that you can find it whenever 

you need to see it after reading this manual thoroughly.

  Make sure you read this ‘Safety Precautions’ carefully before installing the product. 

  Safety Precautions states information that is important to your safety matters. Please follow the instructions 

carefully.

WARNING

 

Hazards or unsafe practices that may result in 

severe personal injury or death.

CAUTION

  

Hazards or unsafe practices that may result in 

minor personal injury or property damage. 

  Follow IEC (International Electrotechnical Commission) standards for the power input and  

ISO (International Standards Organization) standards for input current. 

Содержание NS026NHXEA

Страница 1: ...E 1 ENGLISH ...

Страница 2: ...ling and Connecting the Assembly Pipe of the Indoor Unit 10 Purging the Indoor Unit 11 Cutting or Extending the Pipe 12 Installing and Connecting the Drain Hose of the Indoor Unit 13 Changing Direction of the Drain Hose 14 Assigning Address to Indoor Unit 15 Additional Functions 15 COMPLETING THE INSTALLATION Fixing the Indoor Unit in Place 16 Final Check and Trial Operation 17 Providing Informati...

Страница 3: ...fter completing the installation If the refrigerant gas of the indoor unit leaks and comes into contact with the fan heater space heater or stove harmful gas will be generated Ensure that the national safety code requirements have been followed for the main supply circuit Ensure that a proper ground wire is in place Do not connect the ground to a gas pipe water pipe lightning rod or telephone grou...

Страница 4: ...t may have taken place during transportation and do not install or use damaged equipment After completing the installation run the trial operation If no error occurs explain to the customer how to use and clean the air conditioner according to the user s manual In addition give the installation manual and the user s manual to the customer All of the manufacturing and packaging material used for yo...

Страница 5: ... diagram Wall that prevents vibration and is strong enough to hold the product weight Out of the direct sunlight 1m or more away from theTV or radio to prevent the screen from being distorted or noise from being generated As far away as possible from the fluorescent and incandescent lights so that the remote control can be operated well A place where the air filter can be replaced easily Where it ...

Страница 6: ...lation Manual 1 Remote Control 1 Tools required for installation Tools for test operations Accessories in the Indoor Unit Case Vacuum Pump Backward flowing prevention Manifold Gauge Stud Finder Torque Wrench Pipe Cutter Reamer Pipe Bender Spirit Level Screw Driver Spanner Drill L Wrench Measuring Tape Thermometer Resistance Meter Electroscope Installation Plate 1 PE T3 Foam Tube Insulation 1 Vinyl...

Страница 7: ...ll giving attention to the weight of the indoor unit Note If you mount the plate to a concrete wall using plastic anchors make sure that gaps between the wall and the plate created by projected anchor is less than 20mm Wall 20mm Plastic Anchor If you fix the indoor unit on a window frame 1 Determine the positions of the wooden uprights to be attached to the window frame 2 Attach the wooden upright...

Страница 8: ... Open the front grille 3 Remove the screw securing the connector cover 4 Pass the assembly cable through the rear of the indoor unit and connect the assembly cable to terminals Refer to the picture in page 9 Note Each wire is labeled with the corresponding terminal number 5 Pass the other end of the cable through the 65mm hole in the wall 6 Close the connector cover by tightening the screw careful...

Страница 9: ...ing conductor to the grounding terminals 11 Close the terminal board cover by tightening the screw carefully 12 Connect the power cable to the indoor unit Note In Russia and Europe consult with the supply authority to determine the supply system impedance before installation 1 L 2 N F1 2 N 1 L F2 1 2 1 2 F1 F2 F1 F2 F1 F2 Indoor unit Outdoor unit Indoor unit Outdoor unit CAUTION End of the wire mu...

Страница 10: ...nect the pipe directly from the rear 2 Smooth the cut edges 3 Remove the protection caps of the pipes and connect the assembly pipe to each pipe Tighten the nuts first with your hands and then with a torque wrench applying the following torque Outer Diameter Thickness Torque kgf cm ø6 35 mm 0 8mm 140 170 ø9 52 mm 0 8mm 250 280 ø12 70 mm 0 8mm 380 420 ø15 88 mm 1 0mm 440 480 ø19 05 mm 1 0mm 990 121...

Страница 11: ...of each pipe Result All inert gas exhausts from the indoor unit Note To prevent dirt or foreign substances from getting into the pipes during installation do NOT remove the caps completely until you are ready to connect the pipes The remaining air in the Refrigeration cycle which contains moisture may cause malfunction on the compressor Always contact the service center or a professional installat...

Страница 12: ...mm ø19 05 mm 1 0mm 2 2 mm ø22 23 mm 1 0mm 2 2 mm 5 Check if you flared the pipe correctly see examples of incorrectly flared pipes below Correct Uneven Thickness Cracked Damaged Surface Inclined 6 Align the pipes to connect them easily Tighten the flare nuts first with your hands and then with a torque wrench applying the following torque Outer Diameter Thickness Torque kgf cm ø6 35 mm 0 8mm 140 1...

Страница 13: ...in hose under the refrigerant pipe keeping the drain hose tight 5 Pass the drain hose through the hole in the wall Check if it slants downwards as seen in the picture Shield Drain hose Extension drain hose Make sure the installed direction of the drain hose is correct Inadequate installation may cause condensate water leakage If the drain hose is routed inside the room insulate the hose so that dr...

Страница 14: ...screw into the groove of the drain hose and the outlet of the drain pan 4 Attach the rubber cap with a screwdriver by turning it to the right until it fixes to the end of the groove 5 Check for leakage on both side of the drain outlet CAUTION Make sure the indoor unit is in upright position when you pour water to check for leakage Make sure that the water does not overflow onto the electrical part...

Страница 15: ...It is required to set the RMC address if you install the wired remote controller and or the centralized controller 7 If you install optional accessories such as the wired remote controller centralized controller etc see an appropriate installation manual 8 Refer to the outdoor unit installation manual for the details SW02 MAIN Additional Functions Cover PCB K5 K6 K7 K8 SW05 SW07 No Function ON OFF...

Страница 16: ...assembly cable and drain hose in the lower part of the indoor unit carefully so it does not project from the rear of the indoor unit 4 Hook the indoor unit to the installation plate and move the unit to the right and left until it is securely in place CAUTION Make sure pipe does not move when you install the indoor unit on an installation plate 5 Wrap the rest of the pipe with vinyl tape 6 Attach ...

Страница 17: ...peration 3 Press the button to select Cool or Heat mode In Cool mode useTemp or button and set the temperature at 18 C In Heat mode useTemp or button and set the temperature at 30 C Note Approximately 3 5 minutes later outdoor unit will start to operate and the Cool or Warm air will blow out After 12 minutes of stationary condition check the indoor unit air treatment Cooling mode indoor unit check...

Страница 18: ...tions 3 How to adjust the temperature and the fan speed 4 How to adjust the airflow direction 5 How to set the timers 6 How to clean and replace the filters Note When you complete the installation successfully hand over the User s Manual and this Installation Manual to the user for storage in a handy and safe place Providing Information for User COMPLETING THE INSTALLATION ...

Страница 19: ......

Страница 20: ......

Страница 21: ...ENGLISH Commercial SplitType Room Air Conditioner Cooling and Heating INSTALLATION MANUAL NS NHXEA Series DB98 31943A 1 S E F I P D G ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH EΛΛHNIKA ...

Отзывы: