6
English
Tools and Parts
Parts supplied
Removing the packaging
CAUTION
Remove the carton carefully. Wear gloves to protect against sharp edges.
WARNING
Remove the protective film covering the product before putting into
operation.
•
Hood canopy assembly with blower and LED lamps already installed.
•
6” (15.2 cm) round air transition
•
Duct covers
•
Hardware bag with:
Part
Qty
Part
Qty
5x45 mm
6
5.4x75 mm screws
(for 10x60 mm wall
anchors)
4
8x40 mm
2
Torx 10 adapter
1
3.5x9.5 mm
2
Duct cover bracket
1
4x8 mm
4
Mounting template
1
10 x 60 mm
4
Tools/Materials required
•
Level
•
Drill with 1¼” (3.2 cm),
1
⁄
8
” (3.2 mm), and
1
⁄
16
” (4,8 mm) drill bits
•
Pencil
•
Wire stripper or utility knife
•
Tape measure or ruler
•
Pliers
•
Caulking gun and weatherproof caulking compound
•
Vent clamps
•
Jigsaw or keyhole saw
•
Flat-blade screwdriver
•
Metal snips
•
Phillips & Torx 20 screwdrive
r
Parts needed
•
Home power supply cable
•
½” (12.7 mm) UL listed or CSA approved strain relief
•
3 UL listed wire connectors
•
1 wall or roof cap
•
Metal vent system
Dimensions and Clearances
E
C
D
H
B
A
G
F
NK30M9600WS
NK30M9600WM
NK36M9600WS
NK36M9600WM
A
30”
(76 cm)
36”
(91.2 cm)
B
19
11
⁄
16
” (50 cm)
C*
max. 39
8
⁄
16
” (100.3 cm)
min. 25
7
⁄
16
” (64.5 cm)
D**
max. 43
5
⁄
16
” (110 cm)
min. 29
2
⁄
16
” (73.9 cm)
E
6” (15.24 cm)
F
10
10
⁄
16
” (26.9 cm)
G
13
1
⁄
16
” (33.2 cm)
H
2
3
⁄
8
” (6 cm)
*For vented installations
**For non vented (recirculating) installations
Accesories
Model
NK30M9600WS
NK36M9600WS
NK30M9600WM
NK36M9600WM
Color
Silver Stainless
Matt Black Stainless
Extension
Kit
NK-AE905LWS/AA
NK-AE905LWM/AA
Recirculation
Kit
NK-AF030FNB/AA
Charcoal
Filter
NK-AR050FNB/AA
Installation Requirements
Installation Requirements