6
A
Indoor/outdoor unit installation drawings
MH080FXCA4A
◆
Piping length and the helght
◆
Piping outside diameter
The appearance of the unit may be different from the diagram depending on the model.
System can work with one indoor unit connected, but it is recommended that the total number of indoor unit suggested by
manufacturer are connected to obtain the maximum performance.
Main power switch
A
B
(h)
(H)
600mm(23 5/8")
minimum
300mm(11 13/16")
minimum
300mm(11 13/16")
minimum
600mm(23 5/8")
minimum
Make at least one round :
It will reduce noise and vibration
1 Room max
length
4 Room total max
length
Max height between
indoor unit & outdoor unit
Max height between
indoor units
Dimension
25m(82'-1/4")
70m(229'-7 7/8")
15m(49'-2 9/16")
7.5m(24'-7 1/4")
Composition
A, B, C, D
A+B+C+D
(H)
(h)
3m(9'-10 1/18") as minimum pipe length. It will reduce noise and
vibration. If just one indoor unit is connected this value must be
increased up to 7.5m(24'-7 1/4").
Indoor unit
Outdoor unit
Power supply Ø, V, Hz
TT
026/030/035/052
TT
MH080FXCA4A
1, 208-230, 60
Unit
Outside diameter
Liquid
Gas
TT
026/030/035
TT
1/4"
3/8"
TT
052
TT
1/2"
C
D
NJ***1HXCA_IM_E_33584-1.indd 6
2011-03-28 오후 4:35:32
Содержание NJ***1HXCA
Страница 24: ......