Features and Specifications
2-12
2-13
SAMSUNG PROPRIETARY. DO NOT COPY OR DISTRIBUTE WITHOUT PERMISSION
SAMSUNG PROPRIETARY. DO NOT COPY OR DISTRIBUTE WITHOUT PERMISSION
Feature expansion specification
■ Installation/Service mode
• Unavailable functions are marked inactive and they cannot be set.
• If communication initialization is needed after the setting, the system will reset automatically and communication
will be initialized.
NOTE
Step 1
Step 2
Step 3
Description
Default
Service Timer
Service Call
Number
16-digit phone number Input:
Blank, -, 0-9
-
Last Inspection
Year, Month, Day
-
Installation Data
Year, Month, Day
-
Quiet Mode
Automatic Time
Enable/Disable
Disable
Entry time to Exit time
PM 10:00 ~
AM 06:00
Indoor Zone
Option
Cool/Heat
Selection
Cool & Heat/Heat only
Cool & Heat
Master/Slave
Wired Remote
Master/Slave
Master
Zone Selection
Zone 1/Zone2
Zone 1
Standard
Temperature
Water Outlet/Indoor
Water Outlet
Temperature Unit
Celsius(°C) : 1℃/0.5℃/0.1℃
Fahrenheit(℉) : 1℉
0.5℃
Fahrenheit(℉) : 1℉
Temperature Sensor
Selection
Wired Remote Controller/External
Temperature Sensor
Wired Remote
Controller
Room Temperature
Calibration
Reference
Temperature
-9 to 40°C
-
Calibration Value
-9 to 40°C
0℃
Indoor Zone
Status Information
Central :
ON/OFF
-
Normal Power :
ON/OFF
-
Mode :
Heat/Cool/Auto
-
DHW Power :
ON/OFF
-
DHW Mode :
Economic/Standard/
Power/Forced
-
Water Pump :
ON/OFF
-
BSH :
ON/OFF
-
BSH :
ON/OFF
-
Flow sensor :
lpm
-
Inverter Pump :
0%~100%
-
EEV Step :
0~2000Step
-
Thermostat 1 :
ON/OFF
-
Thermostat 2 :
ON/OFF
-
DHW Thermostat :
ON/OFF
-