background image

ENGLISH-17

03

 
O

tHE

rS

Main 

Menu

Sub 

Menu

Function

Default

Number 

of pages

Description

remarks

5

1

Set/Check 

the optional 

function of 

the wired 

remote 

controller

Set Cooling&Heating/Cooling only 
indoor unit

0

1

0-Cooling&Heating, 
1-Cooling only

2

Wireless remote controller usage

1

1

0 - Disable, 1 - Enable

3

Setting Master/Slave wired remote 
controller

0

1

0 - Master, 1 - Slave 

4

Auto mode usage

1

1

0 - Disable, 1 - Enable

5

Temperature display (°C/°F)

0

1

0 - Celsius (°C),  
1- Fahrenheit (°F)

6

Temperature adjustment unit (0, 
1, 2) [Available when temperature 
display is set to Celsius (°C)]

0

1

0 - 1°C, 1 - 0.5°C, 2 - 1°C

1)* The total option codes are 24 digits. You can set six digits at a time and it is distinguished by page number.

 - Press the  

[Timer]

 button to go to the next page. 

• 

Option setting is from SEG1 to SEG24.

 - SEG1, SEG7, SEG13, SEG19 cannot be set and will not be displayed.
 - SEG2 is a type of option and it cannot be set.
 - ON will be displayed when setting the SEG2~SEG6 and SEG8~SEG12 and OFF will be displayed when setting 

the SEG14~18 and SEG20~24.

• 

Check the operation mode indicator, ON and OFF indicator to distinguish which SEG are displayed.

SEG2~SEG6, SEG8~SEG12

 - ON (Auto 

 Cool 

 Dry 

 Fan 

 Heat)

SEG14~SEG18, SEG20~24

 - OFF (Auto 

 Cool 

 Dry 

 Fan 

 Heat)

CaUtION

SEG1 SEG2 SEG3 SEG4 SEG5 SEG6 SEG7 SEG8 SEG9 SEG10 SEG11 SEG12

0

X

X

X

X

X

1

X

X

X

X

X

SEG13 SEG14 SEG15 SEG16 SEG17 SEG18 SEG19 SEG20 SEG21 SEG22 SEG23 SEG24

2

X

X

X

X

X

3

X

X

X

X

X

On(SEG1~12)

Off(SEG13~24)

<SEG 2, 3>

PaGE 1 

PaGE 6

PaGE 2 

PaGE 7

PaGE 3 

PaGE 8

PaGE 4

PaGE 9

PaGE 5

PaGE 10

<SEG 14, 15>

<SEG 4, 5>

<SEG 16, 17>

<SEG 6, 8>

<SEG 18, 20>

<SEG 9, 10>

<SEG 21, 22>

<SEG 11, 12>

<SEG 23, 24>

SOL WRControl_IM_04148A-00_EN.indd   17

2013-09-25   오전 10:29:13

Содержание MWR-SH00N

Страница 1: ...DB68 04148A 00 DB68 04148A 00 SOL WRControl_IM_04148A 00_EN indd 20 2013 09 25 오전 10 29 14 ...

Страница 2: ...ller MWR SH00N Air Conditioner installation manual imagine the possibilities ThankyouforpurchasingthisSamsungproduct This manual is made with 100 recycled paper SOL WRControl_IM_04148A 00_EN indd 21 2013 09 25 오전 10 29 15 ...

Страница 3: ...paration Safety Precautions 3 Before installation 5 Installation Wired Remote Controller Installation 6 Others Wired Remote Controller Installation Service Mode 15 SOL WRControl_IM_04148A 00_EN indd 2 2013 09 25 오전 10 29 06 ...

Страница 4: ...ace of purchase or a contact center to disassemble or repair the product f f Potential risk of malfunction electric shock or fire The electric work must be done by qualified person according to national wiring regulations and installation guide f f If an unauthorized person performs the installation any resulting defects can cause malfunctions electrical shocks or fire accidents Install the produc...

Страница 5: ... electric shock or product damage Do not install the product in areas exposed to oil or vapor f f Potential risk of product damage or malfunction Do not put undue stress on the power cable f f Potential risk of broken cable and fire Do not install the product in areas with frequent use of acid or alkali spray f f Potential risk of electric shock or product malfunction Do not connect power cable to...

Страница 6: ...led by an installation expert Check and confirm the power is off before installing yourWired Remote Controller Install theWired Remote Controller cables in accordance with the electrical wiring rules and allow it to pass through the inner area of the wall so that other people can t reach it CAUTION External Dimensions Unit mm inch 122 0 4 80 75 0 2 95 16 6 0 65 SOL WRControl_IM_04148A 00_EN indd 5...

Страница 7: ...e communication cable according to the installation environment When wired remote controller is concealed to the wall Withdraw the cable through the hole in the middle of the back cover When wired remote controller is mounted on the wall Decide the direction of the cables to withdraw and remove the thin part of plastic circled part in the illustration in front and back cover When withdrawing the c...

Страница 8: ...o pieces of PVC wire remove the 30 cm 12 inch of the sheath of the cable and install it only with the two pieces of wires Recommended specification AWG21 The following are the specs of the compression ring terminal connected to yourWired Remote Controller PCB Screws on the PCB terminal must be tightened with less than 6 N cm tightening torque If the tightening torque is greater it may damage the s...

Страница 9: ...ain after installation then press the and Set buttons at the same time for more than five seconds The system will reset and tracking will start again 3 During tracking the total number of currently searched indoor units will be displayed 4 It may take about 5 minutes at initial installation or when you re set the Master setting If you want to perform tracking again after installation then press th...

Страница 10: ... unit Outdoor Unit Indoor Unit COM1 F1 F2 COM2 F3 F4 COM1 F1 F2 COM2 F3 F4 COM2 F3 F4 Wired Remote Controller Wired Remote Controller Wired Remote Controller Indoor Unit Indoor Unit Regardless of the indoor group address RMC address only the indoor unit connected to COM2 is individually controlled CAUTION SOL WRControl_IM_04148A 00_EN indd 9 2013 09 25 오전 10 29 08 ...

Страница 11: ...OneWired Remote Controller to control indoor units connected to different outdoor unit Outdoor Unit Indoor Unit Indoor Unit Wired Remote Controller Outdoor Unit COM1 F1 F2 COM2 F3 F4 COM1 F1 F2 COM2 F3 F4 Regardless of the indoor unit s group address RMC address only the indoor units connected to COM2 are controlled in group Regardless of your outdoor units you can control a maximum of 16 indoor u...

Страница 12: ... Indoor Unit COM1 F1 F2 Wired Remote Controller Master COM2 F3 F4 Wired Remote Controller Slave For the slaveWired Remote Controller settings please refer to the sections about the additional functions of the Wired Remote Controller Refer to Additional Functions ofYourWired remote Controller 0 Master 1 Slave CAUTION SOL WRControl_IM_04148A 00_EN indd 11 2013 09 25 오전 10 29 09 ...

Страница 13: ...ntrol one indoor unit or a group of indoor units then you need to initialize your remote controller communication Press the and Set buttons at the same time for more than five seconds f f YourWired Remote Controller will be initialized and the device will search for the indoor units connected to yourWired Remote Controller again SOL WRControl_IM_04148A 00_EN indd 12 2013 09 25 오전 10 29 09 ...

Страница 14: ...isplay A f f The product address for the error will be displayed followed by the error code Example Error 101 occurs for Indoor Unit no 10 Decimal digits Indoor Unit Outdoor unit address hexadecimal digits Indoor unit address hexadecimal digits When an Error Occurs inYourWired Remote Controller f f Only an error code will be displayed No address will be displayed Example Error 601 has occurred at ...

Страница 15: ... set as Slave SUB EEPROM Error For the error codes for your indoor outdoor units refer to the installation manual of each device CAUTION Setting Cancelling the Mode master indoor unit Mode master indoor unit setting is simply selecting an indoor unit that will become standard among many indoor units to prevent mixed operation which one or more indoor units operating in different operation mode Set...

Страница 16: ...ess the Timer button to enter the sub menu setting screen f f Using the buttons select a sub menu number and press the Timer button to enter data setting screen f f When you enter the setting stage the current setting will be displayed f f Refer to the chart for data settings f f Using the buttons select the settings Press the Timer button to move to the next setting f f Press the Set button to sa...

Страница 17: ...s option setting 2 Indoor unit setting Target View Master 3 Address of the registered device 2 Set Check the MAIN address of the indoor unit Main address of the target 1 MAIN address 00H 4FH hexadecimal digits 3 Set Check the RMC address of the indoor unit RMC address of the target 1 Group address 00H FEH hexadecimal digits 5 4 Set Check the product option of the indoor unit Basic option of the ta...

Страница 18: ...o to the next page Option setting is from SEG1 to SEG24 SEG1 SEG7 SEG13 SEG19 cannot be set and will not be displayed SEG2 is a type of option and it cannot be set ON will be displayed when setting the SEG2 SEG6 and SEG8 SEG12 and OFF will be displayed when setting the SEG14 18 and SEG20 24 Check the operation mode indicator ON and OFF indicator to distinguish which SEG are displayed SEG2 SEG6 SEG...

Страница 19: ...hannel RMC 2 Group address Main address of the indoor unit is displayed in hexadecimal digits Please refer to the following table NOTE Hexadecimal Decimal Hexadecimal Decimal Hexadecimal Decimal Hexadecimal Decimal Hexadecimal Decimal 00 0 10 16 20 32 30 48 40 64 01 1 11 17 21 33 31 49 41 65 02 2 12 18 22 34 32 50 42 66 03 3 13 19 23 35 33 51 43 67 04 4 14 20 24 36 34 52 44 68 05 5 15 21 25 37 35 ...

Страница 20: ...utton and select no 1 3 Press Timer button to enter the data setting stage f f When you enter the setting stage the current setting value will be displayed 4 Press button to select no 1 f f The wired remote controller option is set from both cooling and heating to cooling only 5 Press Set button to complete the option setting f f Save the setting value and exit to sub menu 6 Press AirSwing button ...

Отзывы: