Confidential
Chapter 3
Connecting Cables
MT3204 Series Installation Manual v1.0
94
Copyright © 2018, All Rights Reserved.
The method for connecting/disconnecting the CPRI (optical) connector is as
follows:
- For connecting the connector, push the shell to upper side.
- For disconnecting the connector, pull the coupling nut to lower side.
Connecting UDA Cable
To connect a UDA cable, do the following:
Prerequisites
Before proceeding with connecting the UDA cable, make sure that you have the
items mentioned in the table below:
Table 25.
Parts and Tools for Connecting UDA Cable
Category
Description
Installation Section
MMU UDA Port to External alarm device
Cable
UDA Cable Assembly (Cat.5e 24AWG 4P)
Minimum Cable bend Radius
Operation: 5 × OD
Installation: 10 × OD
Connector
External alarm device Check specifications of external device output
terminal per site and prepare fasteners.
MMU
JONHON, Push Pull Type, RJ45MF-CT-07
White Line
[White Line is invisible]
[White Line is visible]
Shell
Coupling Nut
Push
Pull