16. Slide the developer roller out and be particularly careful
with both plastic bushings acting as separators at each end of
the roller. Clean the roller with a soft cloth and use isopropyl
alcohol if needed, to remove all traces of dirt and grease from
the surface. Replenish with conductive grease as needed.
17. Vacuum the area carefully, and avoid touching the
doctor blade.
SAMSUNG ML-2165W (MLT-D101S) TONER CARTRIDGE REMANUFACTURING INSTRUCTIONS
© 2013 UniNet Imaging Inc. All trademark names and artwork are property of their respective owners. Product brand names mentioned are intended to show compatibility only.
UniNet Imaging does not warrant downloaded information. Unauthorized sale, reproduction or distribution of this article is prohibited. For additional support, please contact [email protected]
www.
uninet
imaging.com
15. At the opposite end, remove the screw holding the contact end plate. It must be noted that there is NO conductive spring or
blade doing the electrical work. Instead, a conductive plastic tip at the plate can be found. This is further confirmed by the use
of fair amount of conductive grease both at this bearing and the inside of the metal developer roller.