![Samsung ML-2010/XAZ Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/samsung/ml-2010-xaz/ml-2010-xaz_service-manual_4214382031.webp)
Samsung Electronics
Service Manual
System Overview
3-18
- Output Voltage Falling Time : 50 ms Max
- Output Loading range : 10Mߟ ~ 1000
- Output Control Signal (BIAS-PWM) : the CPU output is HV output when PWM is low.
4) Supply
- Output Voltage : -550 V
8.6%(ZENER using, DEV )
- Input contrast of the output stability degree : under
5 %
- Loading contrast :
5 % or less
- Output Voltage Rising Time : 50 ms Max
- Output Voltage Falling Time : 50 ms Max
- Output Loading range : 10
~ 1000
- Output Control Signal (BIAS-PWM) : the CPU is HV output when PWM is low.
MHV
OPC
DEV
THV
Supply
CN3
LED1
(Error LED)
CN1
LED2
(Toner Save LED)
Switch
Micro Switch
Input