E-
7
ENGLISH
❋
The designs of the unit and the connection valve are subject to change according to the model.
P
REPARING THE
I
NSTALLATION
Respect the clearances and maximum
lengths indicated in the diagram below
when installing the unit.
A
B
C
160 mm
or more
20 mm
or more
Piping length and the height.
100 mm
or more
300 mm
minimum
600 mm
minimum
600 mm
minimum
300 mm
minimum
Circuit breaker
(20A)
Main power switch
220V-240V~, 50Hz
B
(7metres maximum)
A
(15 metres maximum)
A-unit
B-unit
C-unit
Pipe size
Unit
Liquid
1/4
"
1/4
"
1/4
"
GAS
3/8
"
3/8
"
3/8
"
MAX. piping length
( A )
15 m
15 m
15 m
MAX. height
( B )
7 m
7 m
7 m
C-unit
7,000 Btu/h(2.05kW)
B-unit
7,000 Btu/h(2.05kW)
A-unit
12,000 Btu/h(3.51kW)
A
B
INDOOR UNIT
OUTDOOR UNIT
◗
26,000Btu/h
Indoor unit
Outdoor unit
MH26AP1(P2)-07
MH26AP1(P2)-12
MH26AP1(P2)X
1,220-240~,50
Power supply
Ø, V, Hz