PREPARING THE INSTALLATION
Deciding on Where to Install the Air Conditioner (Continued)
MH080FX
A4
Indoor unit
Outdoor unit
Power supply
Ø, V, Hz
026/035/052
MH080FX
A4
1,208-230, 60
Unit
Outside diameter
Liquid
Gas
026/035
1/4"
3/8"
052
1/4"
1/2"
Piping outside diameter
(h)
(H)
A
B
1 Room max
length
4 Room total max
length
Max height between
indoor unit & outdoor unit
Max height between
indoor units
Dimension
82ft
229.7ft
49.2ft
24.6ft
Composition
A,B,C,D
A+B+C+D
(H)
(h)
Piping length and the height
C
D
7.86 inch
or more
6.29 inch
or more
3.93 inch
or more
Main power switch
23.6 inch
minimum
11.8 inch
minimum
11.8 inch
minimum
23.6 inch
minimum
CAUTION:
9.84 ft as minimum pipe length: It will
reduce noise and vibration.
This value must be increased at 24.6 ft
in case it is connected just one indoor
unit.
System can work with one indoor unit connected, but it is recommended that the TOTAL number
of indoor unit suggested by manufacturer are connected to obtain the maximum performance.
The appearance of the unit may be different from the diagram depending on the model.
Make at least one round:
It will reduce noise and vibration