If the power distribution circuit does not have an earth or the earth does not comply with
specifications, an earthing electrode must be installed. The corresponding accessories are
not supplied with the air conditioner.
Select an earthing electrode that complies with the specifications given in
the illustration opposite.
1
Install a green/yellow insulated earthing wire (Ø1.6 mm, section 2 mm2 or
greater):
If the earthing wire is too short, connect an extension lead, soldering the
connection and wrapping it with insulating tape (do not bury the soldered
connection)
Secure the earthing wire in position with staples
4
Dig a hole of the size indicated in the illustration opposite, drive the
earthing electrode into position and cover the top of the electrode
with the excavated soil.
3
Carefully check the installation, by measuring the earthing resistance with
an earthing resistance tester. If the resistance is above the required
level(Example:100Ω), drive the earthing electrode deeper into the ground
or increase the number of earthing electrodes.
5
Connect the earthing wire to the earthing screw on the air conditioner.
6
Determine a suitable location for the earthing electrode:
In damp hard soil rather than loose sandy or gravel soil that has a higher
earthing resistance
Away from underground structures or facilities, such as gas pipes, water
pipes, telephone lines and underground cables
At least two meters away from a lightening conductor earthing electrode
and its cable.
2
The earthing wire for the telephone line cannot be used to
earth the air conditioner.
If the earthing electrode is installed in an area of heavy traffic, its wire
must be connected securely.
Checking Correct Earthing
The outdoor unit must be installed on a rigid and stable base to avoid any increase in
the noise level and vibration, particularly if the outdoor unit is to be installed close to a
neighbour.
If it is to be installed in a location exposed to strong winds or at a height, the unit must be
fixed to an appropriate support (wall or ground).
Fixing the Unit in Position
Position the outdoor unit so that the air flow is directed towards the
outside, as indicated by the arrows on the top of the unit.
1
Attach the outdoor unit to the appropriate support using anchor bolts.
2
Certainly fix up its rubber leg in order to prevent its vibration
and noise.
If the outdoor unit is exposed to strong winds, install shield plates around
the outdoor unit, so that the fan can operate correctly.
3
Carbon
plastic
Steel
core
PVC-insulated green/
yellow wire, 2mm
2
x 3.5 m
To
earthing
screw
50 cm
30
c
m
Model
X
Y
MH040FXEA2A
543
319
MH052FXEA2A
MH060FXEA3A
MH070FXEA4A
MH080FXEA4A
MH18VV1X
MH19VV1X
660
350
INSTALLING THE OUTDOOR UNIT
‘
X’ mm
‘
Y’
m
m
Rubber leg
26926A_IM_E.indd 20