FJM CONSOLE_IB_E_29318A_11.26.08.indd 1
2008-11-26 14:33:21
Страница 1: ...FJM CONSOLE_IB_E_29318A_11 26 08 indd 1 2008 11 26 14 33 21 ...
Страница 2: ...rfalls ocean surf rivers and mountains 2Way air outlet There are two separate air outlets for cooling and heating Having warmer air coming out from the bottom part of the air outlet will spread the warm air evenly throughout the room Stay cooler and warmer in every corner of your room Cost Efficient System Your new air conditioner not only provides maximum cooling power in the summer but can also ...
Страница 3: ... the risk of fire explosion electric shock or personal injury when using your air conditioner follow these basic safety instructions Do NOT attempt Do NOT disassemble Do NOT touch Follow directions carefully Unplug the power plug from the wall socket Make sure the machine is grounded to prevent electric shock Call the contact center for help Recommended instructions or useful information for use T...
Страница 4: ...r conditioner Potential risk of unit malfunction water leakage electric shock or fire Do not connect the air conditioner with heating apparatus or do not attempt to disassemble remodel or repair it by yourself Potential risk of malfunction electric shock or fire If repairs are needed consult the contact center Consult the place of purchase or a contact center to install the air conditioner Imprope...
Страница 5: ... air conditioner using the provided remote control or control accessory if provided Do not unplug to turn off the unit unless there is an immediate danger Do not open the front grille during operation Potential risk of electric shock or unit malfunction Cool air should not flow directly towards people pets and plants It is harmful to your health pets and plants Do not run the air conditioner for a...
Страница 6: ...he air conditioner is operated in dusty areas Inspect the condition electric connections pipes and external case of the air conditioner regularly by a qualified service technician Do not open doors and windows in the room being cooled during operation unless necessary Do not block air conditioner vents If objects block the air flow it may cause unit malfunction or poor performance The packaging ma...
Страница 7: ... by a non qualified service technician Ensure the off on and protection switches are properly installed Do not use the air conditioner if damaged If problems occur immediately stop operation and disconnect the plug from the power supply If the air conditioner will not be used for an extended period of time for example over several months unplug the power from the wall Call the place of purchase or...
Страница 8: ...ditioner on and off 14 Selecting operation mode 14 Auto 15 Cool 16 Dry 17 Fan 18 Heat 19 Adjusting the air flow direction 19 Vertical air flow 19 Horizontal air flow OPERATING ADVANCED FUNCTION 20 20 Setting the Timer 20 On Timer 21 Off Timer 22 Combining ON and Off timer 23 Using the function CLEANING AND MAINTAINING THE AIR CONDITIONER 24 24 Cleaning the exterior 24 Cleaning the filter 24 Air fi...
Страница 9: ...ted and to make the best use of the air conditioner CHECKING THE INDOOR UNIT Carefully unpack your air conditioner and check the unit to make sure it is not damaged Main parts Your air conditioner may slightly look different from illustration shown above depending on your model Air intake Mode indicator and Control button Air outlet Cooling Heating Air outlet Heating Blade pin lever Blade pin leve...
Страница 10: ...when the unit is operating in Fan mode TIMER INDICATOR Timer icon will light up when On Off Timer function is set DEICE INDICATOR This icon will light up when the unit starts to de ice POWER BUTTON Turn On Off the air conditioner The air conditioner will operate in Auto mode POWER INDICATOR Power icon will light up when the unit is in operation REMOTE CONTROL SENSOR Aim the remote control toward t...
Страница 11: ...right corner of the air conditioner You can turn on the air conditioner in Auto mode by pressing the Power button When you set the Air flow switch on Auto it will open the bottom air outlet in Cool Heat and Fan modes However in Silence mode the bottom air outlet will be closed Also in Cool mode the bottom air outlet will be closed within an hour When you set the Air flow switch on Off the bottom a...
Страница 12: ...r Turn on off the air conditioner Mode Set one of the 5 operating modes See pages 14 18 for instructions Fan Adjust how much air flows through the air conditioner with the 4 different fan speeds such as Auto Low Medium High On Timer Set the On Timer on Off Timer Set the Off Timer off Set the mpi mode on off Air swing Activate Deactivate air flow blade movement automatically up and down Temp Increa...
Страница 13: ...re marked the chemical symbols Hg Cd or Pb indicate that the battery contains mercury cadmium or lead above the reference levels in EC Directive 2006 66 If batteries are not properly disposed of these substances can cause harm to human health or the environment To protect natural resources and to promote material reuse please separate batteries from other types of waste and recycle them through yo...
Страница 14: ...ioner Press the Power button on the remote control 2 Set the operation mode Press the Mode button on the remote control until operation mode indicator displays Auto The air conditioner will automatically set the fan speed and operation mode to Cool or Heat depends on the room temperature When you press the Mode button mode will change in order of Auto Cool Dry Fan and Heat 3 Set the Temperature Pr...
Страница 15: ...temperature You can set the desired temperature between the range of 16 C 30 C You can decrease increase the temperature by 1 C 4 Set the fan speed Press the Fan or button on the remote control to set the desired fan speed If room temperature reaches desired value the air conditioner will shut off cooling for a while and just the fan runs When you press the Fan or button fan speed will change in o...
Страница 16: ...ry mode and Auto fan speed indicator appear on the remote control display In Dry mode temperature will be set automatically and will appear on the remote control display When you press the Mode button mode will change in order of Auto Cool Dry Fan and Heat When you are using the remote control make sure correct indicator which matches your selection appears on the remote control display Temperatur...
Страница 17: ...ates in Fan mode When you press the Mode button mode will change in order of Auto Cool Dry Fan and Heat 3 Set the fan speed Press the Fan Speed button on the remote control to set the desired fan speed When you press the Fan or button fan speed will change in order of Low Medium and High When you are using the remote control make sure correct indicator which matches your selection appears on the r...
Страница 18: ...etween the range of 16 C 30 C You can decrease increase the temperature by 1 C 4 Set the fan speed Press the Fan or button on the remote control to set the desired fan speed If room temperature reaches desired value heating will stop for a while When you press the Fan or button fan speed will change in order of Auto Low Medium and High Fan may not operate for about 3 5 minutes at the beginning to ...
Страница 19: ...ner is cooling the room Horizontal air flow Make sure one of the blade pins that stick out of the air flow blades is not broken 1 Move the blade pins left or right to keep the air flow direction in a constant position you prefer To avoid any injuries please move the blade pin after stopping Air Swing mode While the air conditioner cools the room operate the appliance with the air flow blades point...
Страница 20: ...fter first 3 hours 3 Press the Set Cancel button on the remote control to active it on The remote control display will show the hour s you have set The air conditioner will operate automatically at set time and then On timer indicator disappears If On timer is not set within 10 seconds the air conditioner will end setting 4 Set the operating mode Press the Mode button on the remote control until t...
Страница 21: ... hourly unit after first 3 hours 3 Press the Set Cancel button on the remote control to active it on The remote control display will show the hour s you have set The air conditioner will operate automatically at set time and then Off timer indicator disappears If Off timer is not set within 10 seconds the air conditioner will end setting Setting time allows you to change by pressing the Off Timer ...
Страница 22: ...or example If the On timer is set at 3 hours and the Off timer at 5 hours the air conditioner will turn off automatically 3 hours after the set time and then operate for next 2 hours before turning off automatically On timer is longer than Off timer The air conditioner will turn off and then on automatically Set up should be done while the air conditioner is operating For example If the On timer i...
Страница 23: ...ivers and mountains 1 Press the button on the remote control indicator will appears on the remote control display and the air conditioner generates MPI The mode can be selected whether the air conditioner is on off The mode will be on automatically when you turn on the air conditioner To deactivate mode 1 Press the button on the remote control mode you set will be canceled and blue light will turn...
Страница 24: ...ront panel and pull the front cover towards yourself Unhook the safety string and lift up the front panel 2 Grab the handle and slightly press the air filter down to bent the air filter Then pull the Air filter towards you and lift it up to remove the Air filter 3 Clean the Air filter with a vacuum cleaner or soft brush If dust is too heavy then rinse it with running water and dry it in a ventilat...
Страница 25: ... down to bent the air filter Then pull the Air filter towards you and lift it up to remove the Air filter 3 Pull and slide out the Anti allergy filter 4 Clean the Anti allergy filter with a vacuum cleaner or soft brush Then rinse it with running water and dry it in a ventilated area 5 Install the Anti allergy filter back in position 6 Close the front panel Grab the side of the front panel and plac...
Страница 26: ...lter 4 Install the new Deodorizing filter back in position 5 Close the front panel Grab the side of the front panel and place the bottom first then push the panel The replacement timing of the Deodorizing filter differs depending on usage and environmental conditions Even if Deodorizing and Anti allergy filters are installed in an inverted position it will not significantly affect its filtration s...
Страница 27: ...two weeks Check if the air conditioner has just been turned on If so wait 3 minutes The fan speed does not change Check if you selected Auto or Dry mode The air conditioner automatically adjusts the fan speed to Auto in Auto Dry mode Timer function does not set Check if you press the Set Cancel button on the remote control after you have set the time Odors permeate in the room during operation Che...
Страница 28: ...e system functioning Outdoor temp 15 C 24 C DEHUMIDIFYING Indoor temp 18 C 32 C A safety device will stop continuously the system functioning Condensation may occur on the indoor unit with risk to have either water blow off or drops on the floor Indoor humidity below 80 Outdoor temp 5 C 43 C POWER SUPPLY Single phase rated voltage minimum and maximum limit 220 240V 50Hz 198V 264V Any damage occurs...
Страница 29: ...FJM CONSOLE_IB_E_29318A_11 26 08 indd 29 2008 11 26 14 34 21 ...
Страница 30: ... www samsung com lu NETHERLANDS 0900 SAMSUNG 726 7864 0 10 Min www samsung com nl NORWAY 815 56 480 www samsung com no POLAND 0 801 801 881 022 607 93 33 www samsung com pl PORTUGAL 80820 SAMSUNG 726 7864 www samsung com pt SLOVAKIA 0800 SAMSUNG 726 7864 www samsung com sk SPAIN 902 1 SAMSU 72678 www samsung com es SWEDEN 0771 400 200 www samsung com se U K 0845 SAMSUNG 7267864 www samsung com uk ...
Страница 31: ... the possibilities Thank you for purchasing this Samsung product To receive more complete service please register your product at www samsung com global register MH FJEA Series FJM CONSOLE_IB_E_29318A_11 26 08 indd 31 2008 11 26 14 34 22 ...