3. Disassembly and Reassembly
3-2 Replacement of Magnetron
Parts
Explaination Photo
Explaination
Magnetron
Remove the magnetron including the shield
case, permanent magnet, choke coils and
capacitors (all of which are contained in one
assembly).
1.
Disconnect all lead wires from the
magnetron.
2.
Remove nuts (2) securing the magnetron
to the wave guide.
3.
Take out the magnetron very carefully.
NOTE1:
When removing the magnetron, make sure that it antenna does not hit any adjacent parts, or it may be
damaged.
NOTE2:
When replacing the magnetron, be sure to remount the magnetron gasket in the correct position and make
sure the gasket is in good condition.
NOTE3:
Reconnect the lead wire to thermal cutout mounted on the magnetron, before replace the magnetron.
PRECAUTION
During replacement, be certain R.F. anode gasket is in place around anode stub.
PERFORM MICROWAVE LEAKAGE TEST