IMPORTANT SAFETY INSTRUCTIONS

This product requires a three-prong grounded 

outlet. The installer must perform a ground 

continuity check on the power outlet box before 

beginning the installation to insure that the 

outlet box is properly grounded. If not properly 

grounded, or if the outlet box does not meet 

electrical requirements noted (under ELECTRICAL 

REQUIREMENTS), a qualified electrician should be 

employed to correct any deficiencies.

Insure proper
ground exists
before use

CAUTION: For personal 

safety, remove house 

fuse or open circuit 

breaker before 

beginning installation 

to avoid severe or fatal 

shock injury.

CAUTION: For personal safety, the mounting 

surface must be capable of supporting the 

cabinet load and the added weight of this 69 

pound product, plus additional oven loads 

of up to 50 pounds or a total weight of 119 

pounds.

CAUTION: For personal safety, this product 

cannot be installed in cabinet arrangements 

such as an island or a peninsula. It must be 

mounted to BOTH a top cabinet AND a wall.

NOTE: For easier installation and personal 

safety, it is recommended that two people 

install this product.

IMPORTANT – PLEASE READ CAREFULLY. 

FOR PERSONAL SAFETY, THIS APPLIANCE 

MUST BE PROPERLY GROUNDED TO AVOID 

SEVERE OR FATAL SHOCK.

Insure proper
ground exists
before use

Insure proper 

ground exists 

before use.

The power cord of this 

appliance is equipped 

with a three-prong 

(grounding) plug which 

mates with a standard 

three-prong (grounding) 

wall receptacle to 

minimize the possibility 

of electric shock hazard 

from this appliance.

You should have the wall receptacle and circuit 

checked by a qualified electrician to make sure 

the receptacle is properly grounded.

If you have a standard two-prong wall 

receptacle, it is very important to have it 

replaced with a properly grounded three-

prong wall receptacle, installed by a qualified 

electrician.

DO NOT, UNDER ANY CIRCUMSTANCES, CUT, 

DEFORM OR REMOVE ANY OF THE PRONGS 

FROM THE POWER CORD. DO NOT USE WITH 

AN EXTENSION CORD.

ELECTRICAL 

REQUIREMENTS

Product rating is 120 volts AC, 60 Hertz, 13 amps 

and 1.5 kilowatts.This product must be connected to 

a supply circuit of the proper voltage and frequency. 

Wire size must conform to the requirements of the 

National Electrical Code or the prevailing local code 

for this kilowatt rating. The power supply cord and 

plug should be brought to a separate branch circuit 

single grounded outlet of at least 15 A and max 

of 20 A. The outlet box should be located in the 

cabinet above the microwave oven. The outlet box 

and supply circuit should be installed by a qualified 

electrician and conform to the National Electrical 

Code or the prevailing local code.

Manual-Installation_MC17J8100CS_AC_DE68-04129B-02_EN+CFR.indb   3

2017-11-02     2:47:01

Содержание MC17F808KDT

Страница 1: ...to leave these instructions with the Consumer Note to Consumer Keep these instructions for future reference Skill level Installation of this appliance requires basic mechanical and electrical skills...

Страница 2: ...Installing the charcoal filter 13 C Outside back exhaust horizontal duct 14 C1 Adapting the microwave blower for outside back exhaust 14 3 Installation 15 A Preparing the rear wall for outside back e...

Страница 3: ...round exists before use Insure proper ground exists before use The power cord of this appliance is equipped with a three prong grounding plug which mates with a standard three prong grounding wall rec...

Страница 4: ...sed the bottom corners of the damper will have to be cut to fit using the tin snips in order to allow free movement of the damper OUTSIDE BACK EXHAUST EXAMPLE ONLY The following chart contains an exam...

Страница 5: ...traight duct which is longer than their actual physical size When calculating the total duct length add the equivalent lengths of all transitions and adaptors plus the length of all straight duct sect...

Страница 6: ...3 You will find the installation hardware contained in a packet with the unit Check to make sure you have all these parts NOTE Some extra parts are included ADDITIONAL PARTS PART QUANTITY TOP CABINET...

Страница 7: ...space between the cabinets must be 30 wide and free of obstructions This microwave oven is for installation over ranges up to 36 wide If you are going to vent your microwave oven to the outside see th...

Страница 8: ...the rear wall template and for mounting 6 Replace the two screws you removed and carefully screw them back into the case DO NOT OVER TIGHTEN If you over tighten the screws you can strip the screws an...

Страница 9: ...nt overhang Draw a line on the back wall equal to the depth of the front overhang 30 to Cooktop Plate position beneath recessed bottom cabinet with front overhang 30 to Cooktop Draw a horizontal line...

Страница 10: ...dges 1 Draw a Horizontal line on the wall at the bottom of the Rear Wall Template 2 Drill holes for toggle bolts in 3 locations Hole A Hole B Hole C as shown in the illustration above If the location...

Страница 11: ...or is shipped assembled and attached to the filler upper Select the type of ventilation required for your installation and proceed to that section A OUTSIDE TOP EXHAUST VERTICAL DUCT B RECIRCULATING N...

Страница 12: ...have installed the microwave you will need to open the top cabinet and adjust the exhaust adaptor so that you can connect it to the house duct For Front to Back Adjustment Slide the Exhaust Adaptor a...

Страница 13: ...Roll Back of Microwave 5 Place the blower unit back into the opening CAUTION Do not pull or stretch the blower unit wiring Make sure the wires are not pinched 6 Secure the blower unit to the microwav...

Страница 14: ...t counterclockwise 180 Before Rotation After Rotation Back of Microwave Back of Microwave 6 Place the blower unit back into the opening AFTER Fan Blade Openings Facing Back End B End A CAUTION Do not...

Страница 15: ...nly B Attach Mounting Plate to Wall C Prepare Top Cabinet D Mount the Microwave Oven E Connecting Ductwork vertical duct only A PREPARING THE REAR WALL FOR OUTSIDE BACK EXHAUST You need to cut an open...

Страница 16: ...ions on the TOP CABINET TEMPLATE Tape it underneath the top cabinet Drill the holes following the instructions on the TOP CABINET TEMPLATE CAUTION Wear safety goggles when drilling holes in the cabine...

Страница 17: ...uivalent to Depth of Cabinet Recess Cabinet Bottom Shelf Microwave Oven Top Cabinet Front Filler Block Self Aligning Screw 4 Attach the microwave oven to the top cabinet 5 Insert the 2 self aligning s...

Страница 18: ...use fuse or turn the breaker back on Insure proper ground exists before use 5 Plug the power cord into a dedicated 15 amp electrical outlet Insure proper ground exists before use Insure proper ground...

Страница 19: ...19 Memo Manual Installation_MC17J8100CS_AC_DE68 04129B 02_EN CFR indb 19 2017 11 02 2 47 05...

Страница 20: ...DE68 04129B 02 Manual Installation_MC17J8100CS_AC_DE68 04129B 02_EN CFR indb 20 2017 11 02 2 47 05...

Страница 21: ...ces instructions l utilisateur Remarque destin e l utilisateur Conservez pr cieusement ces instructions en vue d une consultation ult rieure Niveau de comp tences L installation de cet appareil n cess...

Страница 22: ...nstallation du filtre charbon 13 C Syst me d vacuation par l arri re conduit horizontal 14 C1 Adaptation du ventilateur du four micro ondes au syst me d vacuation par l arri re 14 3 Installation 15 A...

Страница 23: ...TOUT RISQUE D LECTROCUTION Insure proper ground exists before use Assurez vous que le four est correctement mis la terre avant de l utiliser Le cordon d alimentation de cet appareil est quip d une pri...

Страница 24: ...est utilis les coins inf rieurs du registre devront tre coup s l aide de cisailles afin de le fixer et de permettre au registre de bouger librement SYST ME D VACUATION PAR L ARRI RE EXEMPLE UNIQUEMEN...

Страница 25: ...ritable taille Lors du calcul de la longueur totale du conduit ajoutez les longueurs quivalentes de tous les raccords et adaptateurs la longueur de toutes les parties de conduit droit Le tableau suiv...

Страница 26: ...appareil est livr avec un sachet contenant le mat riel d installation V rifiez que vous disposez de toutes ces pi ces REMARQUE certaines pi ces suppl mentaires sont incluses PI CES SUPPL MENTAIRES PI...

Страница 27: ...doit tre de 30 et d gag Ce four micro ondes est con u pour tre install au dessus d une cuisini re de 36 de large Si vous souhaitez utiliser un syst me de ventilation pour le four micro ondes reportez...

Страница 28: ...vis que vous avez retir es et revissez les soigneusement dans l habillage du meuble NE LES SERREZ PAS EXAG R MENT Si vous serrez les vis avec exc s vous risquez de foirer les filets et d endommager l...

Страница 29: ...he depth of the front overhang 30 to Cooktop Position de la plaque sous un meuble encastr avec d bord frontal 30 de la surface de cuisson Tracez une ligne horizontale afin de marquer la distance dont...

Страница 30: ...r 2 Percez des trous de pour les boulons ailettes 3 emplacements trou A trou B trou C comme indiqu sur l illustration ci dessus Si l emplacement d un trou est align sur un montant percez un trou de 3...

Страница 31: ...la cale sup rieure S lectionnez le syst me de ventilation adapt votre installation et reportez vous la section correspondante A SYST ME D VACUATION PAR LE HAUT CONDUIT VERTICAL B CIRCULATION DE L AIR...

Страница 32: ...aptateur du syst me d vacuation afin de le relier au conduit de l habitation Pour un r glage avant arri re faites glisser l adaptateur du syst me d vacuation autant que n cessaire Plaque du ventilateu...

Страница 33: ...cro ondes 5 Remettez le ventilateur dans son logement ATTENTION ne tirez pas sur les c bles du ventilateur Assurez vous que les c bles n ont pas t coinc s au moment de la remise en place 6 Fixez le ve...

Страница 34: ...une montre Avant la rotation Apr s la rotation Arri re du micro ondes Arri re du micro ondes 6 Remettez le ventilateur dans son logement APR S ouvertures des ailettes du ventilateur dirig es vers l a...

Страница 35: ...ondes E Connexion des conduits conduit vertical uniquement A PR PARATION DU MUR DU FOND POUR LE SYST ME D VACUATION PAR L ARRI RE Vous devez pratiquer une ouverture dans le mur du fond pour installer...

Страница 36: ...Collez le sous le plancher du meuble haut Percez les trous en respectant les instructions figurant sur le GABARIT DU MEUBLE HAUT ATTENTION portez des lunettes de s curit pendant cette derni re op rati...

Страница 37: ...nt l enfoncement du meuble Fond du meuble Haut du four micro ondes Avant du meuble Cale Vis autocentreuse 4 Fixez le four micro ondes sur le meuble haut 5 Ins rez 2 vis autocentreuses travers le fond...

Страница 38: ...ion Insure proper ground exists before use 5 Branchez le cordon d alimentation sur une prise d di e de 15 A Insure proper ground exists before use Assurez vous que le four est correctement mis la terr...

Страница 39: ...19 Notes Manual Installation_MC17J8100CS_AC_DE68 04129B 02_EN CFR indb 19 2017 11 02 2 47 09...

Страница 40: ...DE68 04129B 02 Manual Installation_MC17J8100CS_AC_DE68 04129B 02_EN CFR indb 20 2017 11 02 2 47 09...

Отзывы: