4-3 CD
Alignment and Adjustments
4-4
Samsung Electronics
4-3-1 To Adjust FOCUS BIAS (STOP mode)
1. Set Volt/Div of the oscilloscope to DC 100mV.
2. Ground the scope input and set the waveform to 0v, DC range.
3. Connect the GND terminal of the oscilloscope to Vref,
and (+) terminal to center of AP1.
4. Set WVR4 to 0mV.
4-3-2 To Adjust Tracking Gain (PLAY mode)
1. Connect the ground terminal of the oscilloscope to Vref and (+) terminal to AP2.
2. Load and play the disc.
3. While the disc is running, adjust the gain with WVR1 as shown below.
4-3-3 To Adjust Focus Gain (PLAY mode)
1. Connect the ground terminal of the oscilloscope to Vref and (+) terminal to AP1.
2. Load and play the disc.
3. While the disc is running adjust the gain with WVR2 as shown in the following figure.
4-3-4 To Adjust E/F Balance (PLAY mode)
1. Set Time/Div of the oscilloscope to 2mS.
2. Set Volt/Div of the oscilloscope to 0.5V.
3. Ground the scope input and set to DC, and then
set the DC range.
4. Connect the ground terminal of the oscilloscope to Vref
and (+)terminal to center to AP2.
5. Load and play the disc.
6. Turn WVR1 counterclockwise to the minimum value.
7. Raise WVR3 and adjust the waveform so that its middle
comes to ground of the oscilloscope, (or until the upper half
of waveform becomes symmetrical to the bottom half,A=B).
8. Adjust WVR1 (arrow) for normal sound.
TP2
TP1
VR
NVR1704 NVR1703 NVR1702
NVR1701
TE CENTER FE CENTER
E.F BAL
F.BIAS
0V
Normal Frequency
VOLT/DIV : 0.2V
TIME/DIV : 2mS
VOLT/DIV : 0.2V
TIME/DIV : 2mS
VOLT/DIV : 0.2V
TIME/DIV : 2mS
Low Frequency
High Frequency
A=B
0V
0V
0V
Normal Frequency
VOLT/DIV : 0.1V
TIME/DIV : 2mS
VOLT/DIV : 0.1V
TIME/DIV : 2mS
VOLT/DIV : 0.1V
TIME/DIV : 2mS
Low Frequency
High Frequency
0V
100mV
0V
250mV
0V
100mV