background image

Samsung Electronics

5-2

5-4 High Voltage Capacitor

5-5 High Voltage Diode

5-6 Power Control Relay

5-7 Adjustment of Primary Switch, Door Sensing Switch and Monitor Switch

1. Check continuity of the capacitor with the meter set at the highest resistance scale.
2. Once the capacitor is charged, a normal capacitor shows continuity for a short time, and then indicates 9M

W.

3. A shorted capacitor will show continuous continuity.
4. An open capacitor will show constant 9M

W.

5. Resistance between each terminal and chassis should read infinite.

1. Isolate the diode from the circuit by disconnecting its leads.
2. With the ohm-meter set at the highest resistance scale, measure across the diode terminals. Reverse the

meter leads and read the resistance. A meter with 6V, 9V or higher voltage batteries should be used to
check the front-to back resistance of the diode (otherwise an infinite resistance may be read in both
directions). The resistance of a normal diode will be infinite in one direction and several hundred K

W

in

the other direction.

1. When mounting Primary switch and Interlock

Monitor switch to Latch Body, consult the figure.

2. No specific adjustment during installation of

Primary switch and Monitor switch to the latch
body is necessary.

3. When mounting the Latch Body to the oven

assembly, adjust the Latch Body by moving it so
that the oven door will not have any play in it.
Check for play in the door by pulling the door
assembly. Make sure that the latch keys move
smoothly after adjustment is completed.
Completely tighten the screws holding the Latch
Body to  the oven assembly.

4. Reconnect to Monitor switch and check the

continuity of the monitor circuit and all latch
switches again by following the components test
procedures.

5. Confirm that the gap between the switch

housing and the switch actuator is no more than
0.5mm when door is closed.

1. The relays are located on the PCB Ass'y.  Isolate them from the main circuit by disconnecting the leads. 
2. Operate the microwave oven with a water load in the oven. Set the power level set to high.
3. Check continuity between terminals of the relays after the start pad is pressed.

Precaution

For continued protection against radiation hazard, replace parts in accordance with the wiring diagram and
be sure to use the correct part number for the following switches: Primary and secondary interlock
switches, and the interlock monitor switch (replace all together). Then follow the adjustment procedures
below. After repair and adjustment, be sure to check the continuity of all interlock switches and the
interlock monitor switch.

Alignment and Adjustments

Door Open

Door Closed

Primary switch

¥

0

Monitor switch (COM-NC)

0

¥

Monitor switch (COM-NO)

¥

0

Door Sensing S/W

¥

0

MOUNTING

SCREWS

PRIMARY

MONITOR

DOOR
SENSING

Содержание M308R

Страница 1: ...W SERVICE Manual MICROWAVE OVEN CONTENTS 1 Precaution 2 Specifications 3 Operating Instructions 4 Disassembly and Reassembly 5 Alignment and Adjustments 6 Troubleshooting 7 Exploded Views and Parts List 8 PCB Diagrams 9 Schematic Diagrams ...

Страница 2: ... or inspection within the microwave generating compartments check the magnetron wave guide or transmission line and cavity for proper alignment integrity and connections d Any defective or misadjusted components in the interlock monitor door seal and microwave generation and transmission systems shall be repaired replaced or adjusted by procedures described in this manual before the oven is releas...

Страница 3: ...tor switch 12 If the fuse is blown by the Interlock Monitor Switch Replace all of the following at the same time Primary door sensing switch and power relay as well as the Interlock Monitor Switch The correct adjustment of these switches is described elsewhere in this manual Make sure that the fuse has the correct rating for the particular model being repaired 13 Design Alteration Warning Use exac...

Страница 4: ...o measureany of the high voltages this includes the filament voltage of the magnetron High voltage is present during any cook cycle Before touching any components or wiring always unplug the oven and discharge the high voltage capacitor 2 The high voltage capacitor remains charged about 30 seconds after disconnection Short the negative terminal of the high voltage capacitor to to the oven chassis ...

Страница 5: ...lectronics 2 1 TIMER 15 MINUTES POWER SOURCE 230V 50Hz AC POWER CONSUMPTION MICROWAVE 800W OUTPUT POWER 500W IEC 705 TEST PROCEDURE OPERATING FREQUENCY 2 450MHz MAGNETRON OM52S 20 COOLING METHOD COOLING FAN MOTOR OUTSIDE DIMENSIONS 281 W x 330 5 H x 316 D ...

Страница 6: ...onvenience Features Drinks Snacks Meals Time Feature Stop Button 5 s 1 min h min 3 Operating Instructions 3 1 Control Panel 3 2 Features External Views Door latches Door Control Panel Display Glass Cook Tray 281mm 330 5mm 316mm ...

Страница 7: ...rts or it may be damaged NOTE2 When replacing the magnetron be sure to remount the magnetron gasket in the correct position and make sure the gasket is in good condition 1 Discharge the high voltage capacitor 2 Disconnect all the leads 3 Remove the mounting bolts 4 Reconnect the leads correctly and firmly 4 2 Replacement of High Voltage Transformer PRECAUTION Servicemen should remov their watches ...

Страница 8: ...erlock switch door sensing switch monitor switch and power relay 3 When the above three switches operate properly check if any other part such as the control circuit board blower motor or high voltage transformer is defective 4 4 Replacement of Fuse After replacement of the defective component parts of the door reassemble it and follow the instructions below for proper installation and adjustment ...

Страница 9: ...ly 4 Remove the screw securing the ground 1 Window display should not be disassembled as its mounting tabs will be broken If repair work is difficult replace with Ass y control panel 2 The membrane key board is attached to the escutcheon base with doublefaced adhesive tape Therefore applying hot air such as using of hair dryer is recommended for smoother removal 1 Remove screws securing the contro...

Страница 10: ...t terminal and magnetron case should read open 1 The low voltage transformer is located on the control circuit board 2 Remove the low voltage transformer from the PCB Ass y and check continuity 3 Normal resistor reading is shown in the table Filament Terminals Secondary Terminal Primary Terminals Secondary Approx 160W Filament Approx 0 08W Primary Approx 2 9W Terminals Resistance 1 2 Input 1 300W ...

Страница 11: ...e oven assembly adjust the Latch Body by moving it so that the oven door will not have any play in it Check for play in the door by pulling the door assembly Make sure that the latch keys move smoothly after adjustment is completed Completely tighten the screws holding the Latch Body to the oven assembly 4 Reconnect to Monitor switch and check the continuity of the monitor circuit and all latch sw...

Страница 12: ...tor of 50 times the of centigrade temperature 4 187 x 1000 x DT Output Power 83 83 Heating Time sec 4 187 Coefficient for Water 1000 Water cc DT Temperature Rise T2 T1 5 8 Output Power of Magnetron CAUTION MICROWAVE RADIATION PERSONNEL SHOULD NOT ALLOW EXPOSURE TO MICROWAVE RADIATION FROM MICROWAVE GENERATOR OR OTHER PARTS CONDUCTING MICROWAVE ENERGY 5 3 Alignment and Adjustments 5 9 Procedure for...

Страница 13: ...ur 275 15cc of 20 5ûC 68 9ûF water in a beaker which is graduated to 600cc and place the beaker in the center of the oven 3 Start the oven at the highest power level 4 Set survey meter dual ranges to 2 450MHz 5 Using the survey meter and spacer cone as described above measure arnear the opening of magnetron the surface of the air guide and the surface of the wave guide as shown in the following ph...

Страница 14: ...tive monitor switch NOTE1 4 Shorted HVCapacitor 5 Shorted HVTransformer NOTE2 NOTE 1 All of these switches must be replaced at the same time refer to adjustment instructions Check continuity of power relay contacts and if it has continuity replace power relay also NOTE 2 When HVTransformer is replaced check diode and magnetron also Oven does not accept 1 Key input is not in Sequence Refer to opera...

Страница 15: ...PCB main to the plugged in mode Loud buzzing noise can be heard 1 Loose fan and fan motor Tighten screws of fan motor 2 Loose screws on H V Transformer Tighten screws of H V Transformer 3 Shorted H V Diode Replace H V Diode Oven stops operation during cooking 1 Open or loose wiring of primary Adjust door and latch switches interlock switch 2 Operation of thermal cutout Cavity Sparks 1 Metallic war...

Страница 16: ...Samsung Electronics 7 Exploded Views and Parts List 7 1 Exploded Views 1 33 31 34 35 36 30 28 27 26 29 23 22 25 24 20 21 17 16 18 19 15 14 12 13 11 40 41 10 8 9 2 5 4 3 6 7 32 37 38 42 39 7 1 ...

Страница 17: ... 400 ORG 1 YELLOW 13 DE66 20283B BUTTON SELECT B ABS HR0370D MELON YEL 88099 1 MELON 13 DE66 20283F BUTTON SELECT B ABS G3328 SILK D GRY M308 D AMF 1 GRAY 13 DE66 20283H BUTTON SELECT B ABS EURO YEL M308R Y BWT 1 YELLOW 14 DE72 70213L CONTROL PANEL ABS M308R A BWT MELON GRN 88099 1 MELON 14 DE72 70213K CONTROL PANEL ABS M308R D BWT D GRY G3328 1 GRAY 14 DE72 70213P CONTROL PANEL ABS HR0370D M308R ...

Страница 18: ...15A NUT FLANGE M5 P0 8 MSWR10 FEFZY 4 MGT DE60 10088A SCREW TAP PH PH M3 L8 FEFZY PLAIN 4 PCB MAIN DE60 10088A SCREW TAP PH PH M3 L8 FEFZY PLAIN 3 PCB SUB 7 3 Standard Parts List 7 2 Main Parts List Ref No Parts No Description Specification Q ty Remarks 36 DE39 20145A ASSY POWER CORD MOONSUNG 230V50Hz M308 1 37 DE47 20173A THERMOSTAT PW 2N 90 60 30 187Y 250V7 5A 9 1 38 DE93 20096B ASSY BODY LATCH ...

Страница 19: ...Samsung Electronics 8 1 8 P C B Diagrams 8 1 P C B Diagram ...

Страница 20: ... R011 P18 2001 000429 R CARBON 1KOHM 5 1 8W AA TP 1 8X3 2MM 1 R001 R002 R003 R008 R009 R019 P19 2001 000435 R CARBON 1MOHM 5 1 8W AA TP 1 8X3 2MM 1 R021 P20 2001 000502 R CARBON 20OHM 5 1 4W AA TP 2 4X6 4MM 1 R012 R013 R014 R015 R016 P20 2001 000502 R CARBON 20OHM 5 1 4W AA TP 2 4X6 4MM 1 R017 R018 P21 2001 000780 R CARBON 470OHM 5 1 8W AA TP 1 8X3 2MM 1 R007 P22 2001 000904 R CARBON 620OHM 5 1 8W...

Страница 21: ...SSY NOISE FILTER H V DIODE H V CAPACITOR H V FUSE FAN MOTOR PRIMARY S W POWER RELAY MAIN FUSE MONITOR FUSE THERMAL S W P C B PATTEN C2 C1 RESISTOR 230V 50Hz L V T MONITOR S W LIN CAPACITOR BLU BLU BLK BRN ORG RED BRN BRN R1 L V TRANS KEY BOARD ASSY MAIN P C B DOOR SENSING S W G YEL BLU BLU WHT FM ...

Отзывы: