4-2
4. Troubleshooting
4-1-1. No Power
Symptom
The LEDs on the front panel do not work when connecting the power cord.
-
The SMPS relay does not work when connecting the power cord.
-
The units appears to be dead.
-
Major
checkpoints
The IP relay or the LEDs on the front panel does not work when connecting the power cord if the cables are
improperly connected or the Main Board or SMPS is not functioning. In this case, check the following:
Check the internal cable connection status inside the unit.
-
Check the fuses of each part.
-
Check the output voltage of SMPS.
-
Replace the Main Board.
-
Diagnostics
Does proper DC A3.3V
appear at BD215?
Check a IC201.
Change a main PCB ass’y.
No
Yes
Does proper DC 3.3V, 1.1
appear at BD216, BD201?
No
Yes
LAMP off, power indicator
LED red color?
Yes
No
Check a connection a power cable.
Does proper DC 13V appear at
Pin 1,3,13,15,17 of CN210_N22?
No
Yes
A power is supplied to set?
No
Check a other function.
(No picture part)
Replace a lcd panel.
Change a Assy PCB Power.
Check a IC203, IC204.
Change a main PCB ass’y
1
2
3
Caution
Make sure to disconnect the power before working on the IP board.
Содержание LN22C450E1M
Страница 6: ...1 4 1 Precautions Memo ...
Страница 31: ...4 4 4 Troubleshooting WAVEFORMS 1 R G B Output Signal PC_R Signal PC_G Signal PC_B Signal ...
Страница 33: ...4 6 4 Troubleshooting WAVEFORMS 1 Signal of HDMI Data 2 Digital Output Data ...
Страница 38: ...4 11 4 Troubleshooting WAVEFORMS 1 AV_CVBS Output Signal ...
Страница 40: ...4 13 4 Troubleshooting WAVEFORMS 1 I2C Data 3 Speaker out ...
Страница 102: ...6 9 6 Wiring Diagram 6 2 Wiring Picture HD MODEL C450 22 HD MODEL C450 FHD MODEL C530 C550 ...