4-11
Samsung Electronics
4-2-2 Test run mode and View mode
N
Display Option Key
KEY
KEY operation
7-segment display
K1
Press once : Heating test run
i
[Comparison of weights with other compani
HAUZEN
Other companies
Weight
20Kg
17kg
35%
29kg
wi wi#-"/,wi#-"/,w
Press twice : Defrost test run
i
[Comparison of weights with other compani
HAUZEN
Other companies
Weight
20Kg
17kg
35%
29kg
wi wi#-"/,wi#-"/,w
K2
Press once : Cooling test run
i
[Comparison of weights with other compani
HAUZEN
Other companies
Weight
20Kg
17kg
35%
29kg
wi wi#-"/,wi#-"/,w
K3
Reset
K4
View mode
Refer to View mode display
N
VIEW mode display
Number
of press
Display contents
Display
Units
Segment 1
Segment 2
Segment 3
Segment 4
1
Order frequency
1
Three digits
Two digits
One digit
Hz
2
Current frequency
2
Three digits
Two digits
One digit
Hz
3
Number of indoor heat exchangers
3
Three digits
Two digits
One digit
Hz
4
Out sensor
4
Two digits
One digit
First decimal
°C
5
Discharge sensor
5
Two digits
One digit
First decimal
°C
6
OLP sensor
6
Two digits
One digit
First decimal
°C
7
Cond sensor
7
Two digits
One digit
First decimal
°C
8
Current
8
Two digits
One digit
First decimal
C
9
Fan RPM
9
Three digits
Two digits
One digit
rpm
10
Target discharge temperature
A
Three digits
Two digits
One digit
°C
11
EEV
B
Three digits
Two digits
One digit
step
12
Total indoor heat exchanger capacity
C
Two digits
One digit
First decimal
kW
13
Protection control
D
0 : air conditioning
1 : heating
Protection control
0 : no protection
control
1 : freezing
2 : non-stop
defrosting
3 : over-load
4 : discharge
Frequency state
0 : Normal
1 : Hold
2 : Down
3 : Up_limit
4 : Sown_limit
-
14
Group address of indoor heat
exchanger
E
Three digits
Two digits
One digit
-
15
S/W check
F
-
-
-
-
7-segment display
Key Switch