GY17HS*/GY17HSS*/GY17HSG*
3-1
3 Disassembly and Reassembly
This section of the service manual describes the disassembly and reassembly procedures for the
GY17HS*/GY17HSS*/GY17HSG* TFT-LCD monitors.
WARNING: This monitor contains electrostatically sensitive devices. Use caution when handling
these components.
3-1-1 GY17HS*
Cautions:1. Disconnect the monitor from the power source before disassembly.
2. Follow these directions carefully; never use metal instruments to pry apart the cabinet.
3. R/Cover opening jig : BH81-00001A
1. Place monitor face down on cushioned table.
Remove 6 scrws from grip on the stand and
remove the stand.
2. Disconnect the signal cable from the rear
cover. Lift up the stand to remove the rear
cover.
3. Lift up the rear cover and remove 2 screws
from the shield.
4. Disconnect zebra cable and function cable,
inverter cable, touch power cable from the
shield. Lift up the shield.
Caution : Cables may be easily damaged.
Please use caution when removing shield
cover.
5. Remove 5 screws from the boards. Carefully
remove the silicon glue on the inverter cable
with a razor.
Caution : Lamp wire may be easily
damaged. Please use caution when removing
the silicon.
!
!
Содержание GY17HS Series
Страница 15: ...4 Alignments and Adjustments GY17HS GY17HSS GY17HSG 4 5 Figure 8 2 Figure 8 3 Figure 9 Figure 9 1 ...
Страница 18: ...5 Troubleshooting GY17HS GY17HSS GY17HSG 5 3 1 WAVEFORMS 2 3 4 5 6 ...
Страница 20: ...6 2 GY17HSS 6 Exploded View Parts List 6 2 GY17HS GY17HSS GY17HSG ...
Страница 21: ...6 3 GY17HSG 6 Exploded View Parts List GY17HS GY17HSS GY17HSG 6 3 ...
Страница 41: ...8 Block Diagrams 8 2 GY17HS GY17HSS GY17HSG 8 2 GY17HSS GY17HSG ...
Страница 42: ...GY17HS GY17HSS GY17HSG 9 1 9 Wiring Diagram ...