FACTORY & ELECTRONIC ADJUSTMENT VER1.0
3-1
1. PANEAL voltage adjustment
POWER VOLTAGE ADJUST
1. POWER ON
2. INPUT ALL WHITE PATTERN
3. ADJUST "Vs" VR MEASURE P805 PIN13 TO PIN10 VOLTAGE IS 158 ~ 172 V
4. ADJUST "Va" VR MEASURE P805 PIN1 TO PIN4 VOLTAGE IS 66 ~ 77 V
5. ADJUST "VSD" VR MEASURE P805 PIN1 TO PIN2 VOLTAGE IS 49 V
6. ADJUST "VSCAN" VR MEASURE P805 PIN7 TO PIN2 VOLTAGE IS 88 ~ 92 V
7. ADJUST "Vset" VR MEASURE P805 PIN7 TO PIN10 VOLTAGE IS 208 ~ 222 V
8. ADJUST "VE" VR MEASURE P805 PIN5 TO PIN2 VOLTAGE IS 183 ~ 197 V
VSD
VA
VSCAN
VS
Vset
VE