SAMSUNG Proprietary-Contents may change without notice
Flow Chart of Troubleshooting
This Document can not be used without Samsung's authorization
9-25
PAM100 CHECK
pin17
≥
-65dBm ?
9-10. GSM850 RX
CONTINUOUS RX ON
RF INPUT : 190CH
AMP : -50dBm
NORMAL CONDITION
catch the channel?
CHECK soldered
ANT contact
L101,C107,C108,L121,L100,C106,C112,C136
RFT100
pin 31 : 2.9V ?
PAM100 CHECK
pin11
≥
-65dBm ?
RFT100 CHECK
pin24,25
≥
-65dBm ?
PAM100, RFS100
resolder or change
PAM100
resolder or change
RFT100
resolder or change
UCD300 pin F3, C313,C314
change or resolder
RFT100 CHECK
pin 9,10
freq :26MHz ?
Vp-p : 380mV?
OSC100
change or resolder
RFT100
resolder or change
RFT100
pin 1,2,3,4 Vp-p
: 120mV ?
NO
YES
NO
NO
NO
NO
NO
NO
YES
YES
YES
YES
YES
YES
F100 CHECK
pin7,6
≥
-65dBm ?
F100
resolder or change
YES
NO
GSM Receiver is O.K?
NO
GSM RX path component
resolder or change
YES
END