28
4. Troubleshooting
: Check the voltages of
both heater terminals.
: After operating the heater for more then
10 minutes check if the heater temperature
remains low.
: A normal heater
¶
s resistance is a few
.
A short circuit increases the resistance
to a few M
.
ΊͶ΄
ΊͶ΄
Ϳ
Ϳ
Ϳ
ΊͶ΄
ΊͶ΄
Ϳ
ΊͶ΄
Ϳ
Preheating Error (E-08, E-23, E-26)
Is the heater temperature
very low?
Is the temperature sensor
connected properly?
Is the resistance
between the heater terminals
more then a few M
?
Check the heater
related drive part.
Replace the
heater.
Reconnect the
temperature
sensor properly.
Replace the
heater.
Does the heater work?
S/W Error
After Power > On,
does the symptom continue?
Replace the PCB.