background image

50

© Samsung Electronics Co., LTD  |   

Confidential

MHL Problem

Step2, 3

C1013

MHL IC

L1000

L1001

C1006

C1010

U1003

U1004

Содержание GALAXY Note 8.0

Страница 1: ...Samsung Electronics Co LTD Confidential HW Repair Guide GT N5100 Galaxy Note 8 0 March 2013...

Страница 2: ...t and the product described herein at anytime without obligation on Samsung to provid e notification of such change 2 In data of our company important management technical information is included and...

Страница 3: ...onics Co LTD Confidential Contents 1 Introduction of GALAXY Note 8 2 Service Guide RF calibration IMEI writing Block Diagram 3 Repair Guide Assembly Disassembly Electronic Components SMD parts Trouble...

Страница 4: ...1800 1900 UMTS Quad 850 900 1800 1900 Internal Memory 16GB NAND 2GB RAM External Memory MicroSD up to 64GB Display 8 TFT 1280 x 800 Camera 5MP CMOS 1 3MP CMOS Sensor Accelerometer Magnetic Proximity...

Страница 5: ...load the latest version of RF Calibration program on the PLM System Daseul Launcher Runtime and Model File Run Calibration program Check the Calibration and select correct file Click the Extract Run b...

Страница 6: ...ntial RF calibration 2 3 Check the Calibration Check the System Config items Click the Model Information Type the correct H W version Check the connection port of Phone MSTS and Power Supply Click the...

Страница 7: ...7 Samsung Electronics Co LTD Confidential Click the Start button and connect the phone to Anyway Jig RF calibration 3 3 The Result bar is changed to the GREEN color if the calibration is Passed...

Страница 8: ...the latest version of RF Calibration program on the PLM System Daseul Launcher Runtime and Model File Run Daseul program for IMEI writing Check the IMEI and select correct file Click the Extract Run...

Страница 9: ...lectronics Co LTD Confidential IMEI Writing 2 3 Check the IMEI Write and IMEI Check Check the System Config items Click the Hardware Config Check the connection port of Phone and Power Supply Check th...

Страница 10: ...Writing 3 3 Type the correct IMEI number Click the Model Info Type the correct Software Hardware CSC PDA and SKU_CODE etc Click the Start button and connect the phone to Anyway Jig The Status bar is c...

Страница 11: ...11 Samsung Electronics Co LTD Confidential Block Diagram...

Страница 12: ...12 Samsung Electronics Co LTD Confidential Assembly Disassembly Instruction Assembly...

Страница 13: ...13 Samsung Electronics Co LTD Confidential Assembly Disassembly Instruction...

Страница 14: ...14 Samsung Electronics Co LTD Confidential Assembly Disassembly Instruction...

Страница 15: ...15 Samsung Electronics Co LTD Confidential Assembly Disassembly Instruction Disassembly...

Страница 16: ...16 Samsung Electronics Co LTD Confidential Assembly Disassembly Instruction...

Страница 17: ...17 Samsung Electronics Co LTD Confidential Assembly Disassembly Instruction...

Страница 18: ...Light Proximity sensor Module Sub MIC Power volume key IrDA Module S Pen LCD connector 11pin sub PCB including SPK R connector and Home key FPCB connector SPK R Main MIC Module BT WIFI GPS Antenna on...

Страница 19: ...E600 1107 002190 MoviNAND U701 1203 007657 PMIC UCD400 1205 004510 Audio CODEC U1001 1204 003387 IrDA IC Ant100 Ant101 3712 001375 Ant Contact for GSM WCDMA U900 1209 002142 Magnetic Sensor U201 1205...

Страница 20: ...tor Receiver Ear Jack Light Proximity sensor U104 1203 007333 PAM DCDC U705 1203 007321 IF PMIC C1013 1205 004233 MHL IC HDC400 3711 008347 Connector SPK L HDC300 3711 008347 Connector SIM UCP600 0902...

Страница 21: ...ear etc Power key FPCB Normal Go to the next step 4 Power on the device and check the power on sound or motor vibration Abnormal Front Ass y Normal Go to the next step 5 Check the voltage of the follo...

Страница 22: ...22 Samsung Electronics Co LTD Confidential Power problem Step3 Check the power key FPCB Step2 Vbatt Step5 Step6 U701 C754 C736 C727 C755 AP_PS_HOLD TP C705 OSC700...

Страница 23: ...heck point Result value Defect point 1 Confirm the defect symptom 2 Check the voltage of V_BUS C763 C763 5V Go to the next step If not the correct value Connection status of TA or USB 3 Check the char...

Страница 24: ...24 Samsung Electronics Co LTD Confidential Charging Step2 3 U705 Charging IC C763...

Страница 25: ...k the status of main ANT and Antenna clip Broken dust corrosion No insert Main ant Antenna Clip Normal Go to the next step 4 Check the status crack missing Corrosion etc of RF components F100 Antenna...

Страница 26: ...TD Confidential RF GSM WCDMA Flight mode has to uncheck Compare with normal samples Step2 Step3 Check the main antenna and antenna clip Step4 F100 ASM U100 Transceiver F101 SAW Duplexer PAM100 PAM OSC...

Страница 27: ...r HDC300 Broken dust corrosion SIM socket or Connector Normal Go to the next step 3 Check the voltage of detection pin R330 Notice It should be measured when the phone is started R330 1 8V Go to the n...

Страница 28: ...28 Samsung Electronics Co LTD Confidential SIM card detection problem Step2 3 4 SIM socket R330 R331 HDC300 SIM socket connector...

Страница 29: ...rmal Go to the next step 4 Check the MIC FPCB status Abnormal Speaker R MIC module Normal Go to the next step 5 Check the voltage of C413 Notice It should be measured when the microphone path is activ...

Страница 30: ...30 Samsung Electronics Co LTD Confidential Microphone Problem Step2 3 Check the MIC hole and rubber Step4 Check the MIC FPCB status Step5 U401 C413 Step6 UCD400 Audio CODEC C418 C419...

Страница 31: ...tor HDC400 L in Main PCB HDC101 R in Sub PCB Broken dust corrosion Speaker connector Normal Go to the next step 4 Replace the speaker module Solved speaker Not solved Go to the next step 5 Check the s...

Страница 32: ...32 Samsung Electronics Co LTD Confidential Speaker Problem Step3 Right Speaker Main MIC Left Speaker Check the SPK connector Check the SPK connector L406 L407 C105 C106 Step5...

Страница 33: ...ear cover Ant ANT202 ANT203 Broken dust corrosion BT WIFI Ant ANT202 ANT203 Normal Go to the next step 3 Check the voltage of C233 Notice It should be measured when the BT WIFI path is activated on C2...

Страница 34: ...Electronics Co LTD Confidential BT WIFI Problem You can check the this layout if open the shied cover Step1 Step2 3 4 Step2 BT WIFI Antenna ANT202 ANT203 Check the turn on C233 C250 C251 OSC201 U203...

Страница 35: ...ANT203 Broken dust corrosion BT WIFI Ant ANT202 ANT203 Normal Go to the next step 3 Check the voltage of C209 C211 L200 Notice It should be measured when the GPS path is activated on C209 1 8V C211 L...

Страница 36: ...36 Samsung Electronics Co LTD Confidential GPS GLONASS Problem Step1 Check the turn on Step2 BT WIFI Antenna Step3 4 ANT202 ANT203 C209 C211 L200 C200 C201 U201 GPS IC U200 OSC200...

Страница 37: ...ck the signal or voltage of C804 and C806 Notice It should be measured when the display is activated on If not the correct value LED Backlight IC U802 Normal C804 high 18V C806 V_BATT Go to the next s...

Страница 38: ...38 Samsung Electronics Co LTD Confidential Display Problem Step2 3 4 HDC800 LCD Connector Step2 LCD connector FPCB C800 C801 U800 C806 C804 U802...

Страница 39: ...ct value TSP LDO U902 C913 1 8V Go to the next step 4 Check the voltage of C902 C903 Notice It should be measured when the display is activated on If not the correct value Touch Sensor IC U904 C902 3...

Страница 40: ...40 Samsung Electronics Co LTD Confidential Touch Problem Step2 3 4 5 SLC900 TSP Connector C913 Step2 LCD connector FPCB U902 C902 C903 U904 Touch Sensor IC ZD903 ZD904 ZD905 R682 R683 R908...

Страница 41: ...It should be measured when the S Pen is activated on C1045 C1046 16Mhz Same signal compared with a good PBA Go to the next step If not the correct value OSC1001 5 Check the Signal of following chips C...

Страница 42: ...Electronics Co LTD Confidential S Pen Problem Step2 S Pen connector FPCB Step2 3 4 5 6 SLC1000 S Pen Connector C1035 C1036 C1037 U1005 U1007 U1006 C1045 C1046 OSC1001 C1052 R1042 R1031 R1032 R1041 U10...

Страница 43: ...C922 2 8V Go to the next step 4 Check the clock of R906 Notice It should be measured when the 5M CAM is activated on R906 24Mhz Same signal compared with a good PBA Go to the next step If not the cor...

Страница 44: ...44 Samsung Electronics Co LTD Confidential 5M CAM Problem Step5 R679 Step7 5M CAM Module R678 Step2 3 4 5 6 C920 C917 C922 C921 HDC900 5M CAM connector R906 TP_CAM_I901 TP_CAM_I900 F901 F900...

Страница 45: ...8V Go to the next step 4 Check the clock of R907 Notice It should be measured when the 1 3M CAM is activated on R907 24Mhz Same signal compared with a good PBA Go to the next step If not the correct...

Страница 46: ...46 Samsung Electronics Co LTD Confidential 1 3M CAM Problem Step7 1 3M CAM Module Step5 Step4 R907 TP_CAM_I901 TP_CAM_I900 Step2 3 6 HDC901 1 3M CAM connector C925 C927 C926 Step5 R679 R678 F902...

Страница 47: ...irm the defect symptom 2 Check the voltage of V_BUS C763 C763 5V Go to the next step If not the correct value Charging IC U705 3 Check the voltage of V_BUS_IN C506 C506 5V Go to the next step If not t...

Страница 48: ...48 Samsung Electronics Co LTD Confidential OTG Problem Step2 U705 C763 Step3 Step4 Sub PCB U504 C506...

Страница 49: ...e Defect point 1 Confirm the defect symptom 2 Check the voltage of following chips L1000 C1006 L1001 C1010 L1000 1 2V C1006 3 3V L1001 1 2V C1010 1 8V Go to the next step If not the correct value MHL...

Страница 50: ...50 Samsung Electronics Co LTD Confidential MHL Problem Step2 3 C1013 MHL IC L1000 L1001 C1006 C1010 U1003 U1004...

Страница 51: ...51 Samsung Electronics Co LTD Confidential Q A Question...

Отзывы: