background image

6-3

Samsung Electronics

Parts

Cause

Diagnosis

Remedy

1) Open cathode

Check the terminals with a multimeter to see

Replace magnetron.

of magnetron

if the heater circuit is open.

2) Defective

Check the H. V. Diode for continuity in the reverse and

Replace H. V. Diode.

-

H. V. Diode

normal directions using megger. If there is continuity
in the reverse direction, the H. V. Diode may be faulty.
(In this event H. V. Capacitor will be hot)

3) Shorted

Connect megger leads to quick-connect terminal &

Replace magnetron.

magnetron

body of the magnetron if there is continuity, the
magnetron may be faulty. (In this case  the main
fuse will be blown)

Food is

4) Defective

If there is a crack in the magnetron antenna (dome),

Replace magnetron.

not heated.

magnetron

the magnetron is defective.

5) Poor contact

Check if the screws are secured well to the door hinge.

Replace or adjust.

of primay

and pressing it ON and OFF repeatedly.

interlock switch

6) Open coil of

Check the continuity of primary coil and secondary

Replace the

H. V. Trans-

coil. If there is no continuity, H. V. Transformer is

H. V. Transformer.

former

defective.

7) Shorted H. V.

Check the continuity of capacitor.

Replace the

capacitor

If the capacitor shorts, the fuse blows

H. V. Capacitor.

8) Monitor fuse

Check the monitor fuse

Replace the

blown out

(on the noise filter)

Monitor fuse

6-2 Unsatisfactory Cooking

Symptom

Related Parts

Check Points

Remedy

Microwave

H.V.Transformer

1) Check if the primary and secondary coil is open or shorted.

Replace.

cooking does

*  Resistance of primary coil: Approx. 2.15 Ω

not work.

Resistance of secondary coil: Approx. 123 Ω

2) Check if the MGT Heater Voltage is approx. 3.3V AC.

Caution : High voltage !

H.V.Capacitor

Check continuity of capacitor between two

Replace.

terminals with H.V.wire lead removed.
The  resistance should be approx. 10M

, it's failure.

H.V.Diode

1) If there is no continuity in forward, direction the H.V.Diode is open.

Replace.

2) If there is continuity in reverse direction, it's shorted.

Fan motor

Fan motor

Check if the motor coil is open.

Replace.

does not rotate.

6-3 Part Check List

Troubleshooting

Содержание G2613C

Страница 1: ...NTENTS G2613C 400 560 800W 120 240 0 1 2 3 4 5 6 7 8 9 10 20 30 40 50 60 1 Precaution 2 Statements 3 Operating Instructions 4 Disassembly and Reassembly 5 Alignment and Adjustments 6 Troubleshooting 7...

Страница 2: ...or inspection within the microwave generating compartments check the magnetron wave guide or transmission line and cavity for proper alignment integrity and connections d Any defective or misadjusted...

Страница 3: ...es interlock monitor switch 12 If the fuse is blown by the Interlock Monitor Switch Replace all of the following at the same time Primary door sensing switch and power relay as well as the Interlock M...

Страница 4: ...oltage capacitor to to the oven chassis Use a screwdriver 3 High voltage is maintained within specified limits by close tolerance safety related components and adjustments If the high voltage exceeds...

Страница 5: ...0Hz AC POWER CONSUMPTION MICROWAVE 1 350W GRILL 1 000W OUTPUT POWER 800W IEC 705 OPERATING FREQUENCY 2450MHz TIMER 60 MINUTES COOLING METHOD AIR COOLING MAGNETRON OM75SH 31 OUTSIDE DIMENSIONS 489 W x...

Страница 6: ...3 1 Samsung Electronics 3 Operating Instructions 3 1 Control Panel G2613C 400 560 800W 120 240 0 1 2 3 4 5 6 7 8 9 10 20 30 40 50 60 DEFROST INSTANT COOK...

Страница 7: ...level to 100 maximum by turning COOKING POWER CONTROL knob 3 Set the time to 4 to 5 minutes by turing TIMER knob Important If any problem is experienced in the operation of the oven please refer to th...

Страница 8: ...LOW 15 120W GRILL 1000W 3 5 Adjusting the Cooking Time During Cooking Stopping the Cooking Adding Extra Time To stop the cooking Press Temporarily Open Door To resume cooking close the door Completely...

Страница 9: ...cover NOTE 1 When removing the magnetron make sure that its antenna does not hit any adjacent parts or it may be damaged NOTE 2 When replacing the magnetron be sure to remount the magnetron gasket in...

Страница 10: ...ewdriver into the gap between Door E and Door C to remove Door C Be careful when handling Door C because it is fragile Following the procedure as shown in the figure insert and bend a thin metal plate...

Страница 11: ...ter replacement of the defective component parts of the door reassemble it and follow the instructions below for proper installation and adjustment so as to prevent an excessive microwave leakage 1 Wh...

Страница 12: ...onnectors from the transformer terminals and check continuity 2 Normal resistance readings should be as follows Secondary Approx 123 Filament Approx 0 Primary Approx 2 15 Room temperature 20 C Magnetr...

Страница 13: ...es and the interlock monitor switch all together Then follow the adjustment procedures below After repair and adjustment be sure to check the continuity of all interlock switches and the interlock mon...

Страница 14: ...and time tests with accurate equipment 1 Fill the one liter glass vessel with one liter of water 2 Stir water in glass vessel with thermometer and record glass vessel s temperature as T1 10 1 C 3 Afte...

Страница 15: ...vice make a repair record for the measured values and keep the data 2 If the radiation leakage is more than 4 mW cm2 after determining that all parts are in good condition functioning properly and the...

Страница 16: ...fuse 2 Poor contact of Check continuity of power supply cord Also check Adjust or replace the power cord whether the power cord is securely wired power supply cord 3 Defective lamp The fan motor rota...

Страница 17: ...oose screw 1 Defective If the timer does not operate with 230V applied to the Replace timer Timer does timer motor terminals the timer motor amy be faulty not operate 2 Defective The lamp does not lig...

Страница 18: ...heck the continuity of primary coil and secondary Replace the H V Trans coil If there is no continuity H V Transformer is H V Transformer former defective 7 Shorted H V Check the continuity of capacit...

Страница 19: ...arts List 7 1 Main Exploded View M1 M3 M27 M29 M35 C6 C5 C4 C7 C2 C8 C1 C3 M32 M31 M34 M33 M18 M21 M22 M23 M19 M36 M37 M38 M25 M26 M2 M5 M28 M6 M9 M10 M13 M39 M15 M16 M17 B1 B2 B2 B3 B4 M7 M8 M30 M24...

Страница 20: ...18 DE66 90113A LEVER DOOR PP TB53 GH10 T2 5 W31X100 5 12G NTR 3RD W 1 M19 DE26 10121B TRANS H V SHV 745EC1 230V 50HZ KEC 2230V 1 M20 DE94 00089W ASSY DOOR G2613C XEC PURE WHT SESA 1 M21 DE61 50106A BR...

Страница 21: ...List Ref No Parts No Description Specification Q ty Remarks C 1 DE66 20281A BUTTON PUSH ABS 15g T2x37x86 WHT 3RD W B D 1 C 2 DE61 70076A SPRING BUTTON HSWR PI0 6 1 C 3 DE64 10162A KNOB ABS WHT 3RD W 2...

Страница 22: ...S 4X12 TOOTHED 1 BKT GRI DE60 10082H SCREW A 2S 4X12 TOOTHED 2 CN BOX DE60 10082H SCREW A 2S 4X12 TOOTHED 1 CV AIR DE60 10082H SCREW A 2S 4X12 TOOTHED 2 MO FAN DE60 10082H SCREW A 2S 4X12 TOOTHED 5 PN...

Страница 23: ...GT TCO LAMP DRIVE MOTOR FAN MOTOR TIMER MOTOR GRILL HEATER GRILL TCO PRIMARY SWITCH MONITOR SWITCH FUNCTION ROTARY MWO MODE CYCEL MODE GRILL MODE PRIMARY LATCH SWITCH SECONDARY LATCH SWITCH MONITOR SW...