39
4. Troubleshooting
4-1 Failure Display Codes (02 Version)
Safety error
“E-08” or
“E-0A”
* Replace sub PCB
* Solder again if pattern is damaged
or parts is wrong contacted.
No
* DLB, Bake, Broil,convection relay
check.(Nomal:
Ω)
* Check whether there is any damaged
parts of sub PCB pattern.
* Measure oven sensor resistance.
(1080Ω at the room temperature)
* Check the connecting condition of
harness related with oven sensor.
* Check connector and harness connected to Sub PCB.
* Check whether harness on connector
(CN04,CN05) of sub PCB is connected normally into the
connector(CN04,CN05) or not.
Disconnect power and sub PCB
Ok
Ok
Ok
No
END
*Reconnect after replacing the oven
sensor.
No
Replace or repair the harness.
With replacing sub PCB or main PCB, and make set work. No
Replace sub PCB or main PCB
END
END
CN04, CN05
CN04, CN05
∞
DLB Relay
DLB Relay
Bake Relay
Bake Relay
Convection
Relay
Convection
Relay
Broil Relay
Broil Relay
Sub PCB
Sub PCB
Main PCB
Main PCB
CN04, CN05
CN04, CN05
Sub PCB
Sub PCB