65
4. Troubleshooting
4-2 Electrical Malfunction
Component testing procedures
WARNING
ELECTRICAL SHOCK HAZARD
Disconnect power before servicing the range . Replace all panels before operating range . Failure to do so
can result in death or electrical shock .
FIGURE
TESTS MEASURE
RESULTS
Broil Heater
Broil Heater
*
Measure resistance values of
heater’s terminal after taking off
harness from heater .
*
Measure voltage of heater’s terminal
after making oven work by pressing
broil keypad .
*
Approx : 13 ~ 16Ω
(at the room temperature)
*
Terminal voltage of Broil heater :
AC 240V
*
Replace or repair harness
*
Replace or repair sub PCB
Bake Heater
Bake Heater
*
Measure resistance values of
heater’s terminal after taking off
harness from heater .
*
Measure voltage of heater’s terminal
after making oven work by pressing
bake keypad . (Make sure that
voltage has to be measured for more
than 1 minute because heater is
supposed to on-off cycling work .)
*
Approx : 26 ~ 30Ω
(at the room temperature)
*
Terminal voltage of bake heater :
AC 240V
*
Replace or repair harness
*
Replace or repair sub PCB
Convection Heater
Convection Heater
*
Measure the resistence values of
heater’s terminal after taking off
harness from heater .
*
Measure the voltage of heater’s
terminal after having oven worked,
by pressing convection bake keypad .
(Make sure that voltage has to be
measured for more than 1 minute
because heater is supposed to on-off
cycling work .)
*
Approx : 70 ~ 73Ω(at the room
temperature)
*
Terminal voltage of convection
heater :
AC 240V
*
Replace or repair harness
*
Replace or repair sub PCB
Drawer Heater
Drawer Heater
*
Measure the resistance of values of
heater, after taking off harness from
heater .
*
Measure the terminal voltage of
heater after making oven work by
pressing warming drawer keypad .
*
Approx : 22 ~ 25Ω
(at the room temperature)
*
Terminal voltage of Drawer
heater : AC 120V
*
Replace or repaire harness
*
Replace or repaire sub PCB