Part
Figure
Description
Pump-Drain
Preparation:
•
Disassemble the shutter.
- Refer the “Cover base” disassembly section.
1.
Remove the Pump-drain by rotating it
counterclockwise lifting up the hook holding it in
place slightly.
Caution
Make sure to remove remain water in the
dishwasher. If not, water will spill on to the floor.
:
The Pump-drain has a seal .
2. Disconnect the two(2) Pump-drain connectors.
Sensor-Turbidity
Preparation:
•
Disassemble the cover base.
- Refer the “Cover base” disassembly section.
1. Remove the sensor-turbidity connector.
2. Remove the two hooks from the sensor-turbidity.
Caution
Use a flat screwdriver carefully to remove it from
the Assy sump preventing breakage.
: The sensor-turbidity has a seal .
※
Reassembly is in the reverse order of the removal.
24 _ Disassembly and Reassembly