Troubleshooting_59
Error Type
Error mode
Checking method
Corrective actions
Display error
None
1. Check the connections for the Display LED connector part.
- Reconnect the connectors for Display LED.
2. Check the Display LED.
- Faulty: Replace the Display LED and Sub PBA.
Dry error
None
1. Check the wire connections for the Fan Motor.
- Reconnect the Fan Motor connectors.
2. Check the resistance of the Fan Motor coil.
(Remove the connector before measuring.)
1RUPDO$SSUR[aȍ
- Faulty: Replace the Fan Motor assy.
3. Check the operation of the Fan Motor Relay
: Check the operating voltage between the red wire of the
CN201 connector and the Black wire of the CN101
connector.
Normal: 110V ~ 120V (while operating)
- Faulty: Replace the Main PBA assy.
4. After Method 1~3, if dry performance is bad.
- Faulty : Replace the Dry duct replace.