Installation
English
19
STEP 3
Connect the electrical wiring
First, read through the “
Electrical requirements
” section, and then follow these steps.
3-wire system
A
B
E
C
D
A.
External ground connector
B.
Neutral grounding wire (white)
C.
Center silver-colored terminal block
screw
D.
Neutral wire (white or center wire)
E.
¾” (1.9 cm) UL-listed strain relief
1.
Loosen or remove the center terminal
block.
2.
Connect the neutral wire (white or
center wire) of the power cable to the
center, silver-colored terminal screw of
the terminal block. Tighten the screws.
3.
Connect the other wires to outer
terminal block screws. Tighten the
screws.
4.
Tighten the strain relief screws.
5.
Insert the terminal block cover into the
rear panel of the dryer. Then, secure the
cover with a hold-down screw.
CAUTION
• To convert from the 4-wire system
to 3-wire system, connect the ground
strap to the terminal block support to
ground the dryer frame to the neutral
conductor.
• Ring-type terminals are recommended.
If using strap terminals, make sure they
are tightened.
DV8650M-03170X-01_EN.indd 19
3/6/2017 10:55:50 PM
Содержание DVG52M8650V
Страница 1: ...Dryer User manual DVE G 52M8650 DV8650M 03170X 01_EN indd 1 3 6 2017 10 55 31 PM ...
Страница 55: ...Memo DV8650M 03170X 01_EN indd 55 3 6 2017 10 56 02 PM ...
Страница 57: ...Sèche linge Manuel d utilisation DVE G 52M8650 DV8650M 03170X 01_CFR indd 1 3 6 2017 10 54 33 PM ...
Страница 111: ...Mémo DV8650M 03170X 01_CFR indd 55 3 6 2017 10 55 05 PM ...
Страница 113: ...Secadora Manual del usuario DVE G 52M8650 DV8650M 03170X 01_MES indd 1 3 6 2017 10 56 57 PM ...
Страница 167: ...Notas DV8650M 03170X 01_MES indd 55 3 6 2017 10 57 25 PM ...