Installation
English
24
Installation
4-wire system
F
A B
C L2
L1
D
E
A.
External ground connector
B.
Neutral grounding wire (white)
C.
Center silver-colored terminal block
screw
D.
Neutral wire (white or center wire)
E.
¾” (1.9 cm) UL-listed strain relief
F.
Neutral wire (white or center wire)
1.
Remove the external ground
connector’s screw and connect the
ground wire (green or unwrapped) of
the power cable to the screw.
CAUTION
- To connect the ground wire to the
neutral position without through
contact A (cabinet ground), contact
a technician. This is not user
serviceable.
- Ring-type terminals are
recommended. If using strap
terminals, make sure they are
tightened.
2.
Loosen or remove the screws from the
center terminal block.
3.
Connect the neutral wire (white or
center wire) and ground wire (white) to
the center screw of the terminal block.
Tighten the screw.
4.
Connect the other wires to the outer
terminal block screws. Tighten the
screws.
5.
Tighten the strain relief screws.
6.
Insert the tab of the terminal block
cover into the rear slot of the dryer.
Secure the cover with a hold-down
screw.
CAUTION
Connect the power cord and check L1/L2/N voltage. If the voltage is low, it may not heat
properly. Review the “
if needed.
Untitled-6 24
2020-12-04 4:25:27
Содержание DVEG50T5300 Series
Страница 1: ...Dryer User manual DVE G 50R5400 DVE G 50T5300 DVE G 50R5200 Untitled 6 1 2020 12 04 4 25 22 ...
Страница 61: ...Secadora Manual del usuario DVE G 50R5400 DVE G 50T5300 DVE G 50R5200 Untitled 27 1 2020 11 18 8 15 40 ...
Страница 121: ...Notas Untitled 27 61 2020 11 18 8 16 18 ...
Страница 122: ...Notas Untitled 27 62 2020 11 18 8 16 18 ...
Страница 123: ...Notas Untitled 27 63 2020 11 18 8 16 18 ...