Installation requirements
English
11
Ducting requirements
Recommended
Use only for short-run installation
Weather hood
type
4” (10.2 cm)
2.5” (6.4 cm)
No. of 90°
elbows
Rigid
Rigid
0
80 ft. (24.4 m)
74 ft. (22.6 m)
1
68 ft. (20.7 m)
62 ft. (18.9 m)
2
57 ft. (17.4 m)
51 ft. (15.5 m)
3
47 ft. (14.3 m)
41 ft. (12.5 m)
NOTE
* Use a 4-inch (10.2 cm) diameter rigid aluminum or galvanized steel duct.
If you integrate the dryer’s vent system with an existing exhaust system:
• Make sure the exhaust system meets all applicable local, state, and national regulations.
• Verify you are not using flexible plastic duct.
• Make sure to check for and remove all lint buildup from inside the existing ducts.
• Confirm the duct is not kinked or crushed.
• Make sure the exhaust hood damper opens and closes freely.
Manometer measurements
The static pressure in any exhaust system must not exceed 0.83 inches of water column
or be less than 0. Note that these values are measured with the dryer running with a
manometer presented to the exhaust duct that connects to the dryer. The dryer tumbler
must be empty and lint filter clean.
DV8650M_DC68-03170X-05_EN.indd 11
2019-06-03 5:08:08
Содержание DVE52M8650 Series
Страница 1: ...Dryer User manual DVE G 52M8650 DV8650M_DC68 03170X 05_EN indd 1 2019 06 03 5 08 07 ...
Страница 55: ...Memo DV8650M_DC68 03170X 05_EN indd 55 2019 06 03 5 08 20 ...
Страница 57: ...Sèche linge Manuel d utilisation DVE G 52M8650 DV8650M_DC68 03170X 05_CFR indd 1 2019 06 03 5 07 07 ...
Страница 111: ...Mémo DV8650M_DC68 03170X 05_CFR indd 55 2019 06 03 5 07 20 ...
Страница 113: ...Secadora Manual del usuario DVE G 52M8650 DV8650M_DC68 03170X 05_MES indd 1 2019 06 03 5 07 39 ...
Страница 167: ...Notas DV8650M_DC68 03170X 05_MES indd 55 2019 06 03 5 07 52 ...